Hacktoberfest 2026: die Issues, die Maintainer für den Oktober markiert haben – offen und einsteigerfreundlich. Hacktoberfest-Issues durchsuchen

Battery separators: amorphous polymer models (carboxylated cellulose, nylons) built with an external tool, run in ECCE

Offen
#359 0 Kommentare 0 Reaktionen 0 zugewiesene Personen Auf GitHub ansehen

Dieses Issue hat noch niemand übernommen.

Bewertung

Schwierigkeit
5/5
Geschätzter Aufwand
Über eine Woche
Anfängerfreundlichkeit
20/100
Issue-Typ
Feature
Klarheit
Größtenteils klar
Aktivitätsstatus
Aktiv

Rechercherichtung

Start by reviewing related issues #357 and #180 to understand the planned pore filler and analysis work. Compare the listed builders and force fields against the stated GROMACS, material coverage, licensing, and platform criteria, then check relevant literature for parameter credibility. Done means selecting a supported approach and defining the model and analysis needed for the proposed polymer separators.

Vom Indexierungsmodell aus dem Issue-Text verfasst.

Beschreibung

Battery separators are amorphous porous polymers, so they cannot be made from a unit cell. The two classes of interest are carboxylated celluloses and nylons. The aim is to build such models with an external tool and set up, run and analyse them in ECCE (GROMACS).

To be evaluated (nothing is installed or decided):

  • Builders for amorphous polymers: polyply (writes GROMACS topologies and coordinates directly), EMC, Polymatic, PySIMM, RadonPy. Criteria: GROMACS output, force-field coverage for carbohydrates (carboxylated cellulose) and polyamides (nylons), licence, platform support.
  • Force fields: for example GLYCAM/CHARMM36 carbohydrate parameters for cellulose derivatives, GAFF/OPLS-AA for polyamides. Which ones are credible for these materials still needs checking against the literature.
  • Model: a polymer slab or block with a pore (slit or cylinder) filled with electrolyte. The general region filler planned with #357 would fill the pore.
  • Scale: commercial separator pores are tens of nanometres, while an atomistic box is about 10 nm. MD addresses local behaviour (wetting, ion and solvent structure and diffusion at the polymer surface and in nanopores); membrane-scale porosity and tortuosity normally come from imaging or pore-network models.
  • Analysis: diffusion, conductivity and transference number (#180); porosity and pore-size distribution of the model (new).

Related: #180, #183, #341, #357.

Vorherrschende Sprache
C
Sterne
10
Forks
8
Ø Merge
21 Min.
Gemergte PRs (30 T.)
1

Entwicklungsumgebung

Dieses Projekt bietet weder Dev-Container noch Dockerfile noch Beitragsleitfaden – die Einrichtung liegt bei Ihnen. Beginnen Sie mit der README; die allgemeinen Schritte stehen in unserem Leitfaden für den ersten Beitrag.

Erste Schritte

  1. Lesen Sie das ganze Issue und danach den Beitragsleitfaden des Projekts.
  2. Schreiben Sie ins Issue, dass Sie es übernehmen — das erspart doppelte Arbeit.
  3. Forken Sie das Repository und arbeiten Sie in einem Branch.
  4. Öffnen Sie einen Pull Request, der die Issue-Nummer nennt.

Mehr aus FriendsofECCE/ECCE

Alle Issues in FriendsofECCE/ECCE

Ähnliche Issues

Weitere Issues zu C

Neue Issues direkt in Ihr Postfach

Eine kurze Übersicht über anfängerfreundliche GitHub-Issues.