Consider adding short-to-ground fault option to the bus model

Open
#605 1 comment 1 reaction 1 assignee View on GitHub

Maintainers usually reply within 1 day

@lukelowry is already working on this.

Since Oct 5, 2026.

Assessment

This issue has not been assessed yet.

Description

new model
Summary

Add option to the PhasorDynamics::Bus to create short-to-ground fault, as opposed to using a separate BusFault object attached to the bus.

Rationale

With current implementation one needs to modify the case file whenever one needs to add a fault. This becomes impractical, especially when carrying out a sweeping contingency for a large case.

Description

Implement fault within PhasorDynamics::Bus model itself in a similar fashion as it was done in BusFault component. This would add following parameters to the Bus model:

  • Fault on/off (bool)
  • Short-to-ground impedance (RealT)

Jacobian stamp for the "fault-able" bus would need to be augmented with additional derivatives, which would be set to zero when there is no fault.

Additional information

No response

Dominant language
C++
Stars
27
Forks
11
Avg merge
2d 21h
Merged PRs (30d)
15

Getting set up

Open in Codespaces

Starts the project's dev container in your browser, under your own GitHub account.

First steps

  1. Read the whole issue, then the project's contributing guide.
  2. Comment on the issue to say you are picking it up — it saves two people doing the same work.
  3. Fork the repository and make your change on a branch.
  4. Open a pull request that references the issue number.

More from ORNL/GridKit

All issues in ORNL/GridKit

Similar issues

More C++ issues

Get new issues in your inbox

A short digest of beginner-friendly GitHub issues.