Consider adding short-to-ground fault option to the bus model

未关闭
#605 1 条评论 1 个 reaction 已指派 1 人 在 GitHub 查看

维护者通常 1 天内回复

@lukelowry 已经在做这个了。

开始于 2026年10月5日。

评估

这个 Issue 还没有评估数据。

描述

new model
Summary

Add option to the PhasorDynamics::Bus to create short-to-ground fault, as opposed to using a separate BusFault object attached to the bus.

Rationale

With current implementation one needs to modify the case file whenever one needs to add a fault. This becomes impractical, especially when carrying out a sweeping contingency for a large case.

Description

Implement fault within PhasorDynamics::Bus model itself in a similar fashion as it was done in BusFault component. This would add following parameters to the Bus model:

  • Fault on/off (bool)
  • Short-to-ground impedance (RealT)

Jacobian stamp for the "fault-able" bus would need to be augmented with additional derivatives, which would be set to zero when there is no fault.

Additional information

No response