Upgraded HTTP/2 CONNECT streams cannot be reset, so a failed tunnel looks like a clean close
I maintainer di solito rispondono entro 4 giorni
Nessuno ha ancora preso questa issue.
Valutazione
- Difficoltà
- 4/5
- Tempo stimato
- 3-5 giorni
- Idoneità per principianti
- 55/100
- Tipo di issue
- Funzionalità
- Chiarezza
- Abbastanza chiara
- Stato di attività
- Attiva
- Stack tecnologico
- rust
- Ambito
- backend-api-design, networking
Direzione di ricerca
Start with proto::h2::upgrade::pair, H2Upgraded::poll_shutdown, and UpgradedSendStreamTask::tick to trace how shutdown becomes END_STREAM. Then inspect how Upgraded::downcast reaches upgrade implementations. Done means an HTTP/2 CONNECT upgrade can queue CONNECT_ERROR while HTTP/1 upgrades remain unchanged, including the reported tunnel-reset scenario.
Scritto dal modello di indicizzazione a partire dal testo della issue.
Descrizione
Is your feature request related to a problem? Please describe.
A server that accepts an HTTP/2 CONNECT (or extended CONNECT) gets the
tunnel from hyper::upgrade::on as an Upgraded. hyper offers no way to end
that stream with an error. Dropping the Upgraded, or shutting it down, always
sends a clean END_STREAM. A proxy whose tunnelled connection fails therefore
cannot tell the client, and the client cannot tell a failed tunnel from a
complete one.
RFC 9113, section 8.5:
A proxy treats any error in the TCP connection, which includes receiving a
TCP segment with the RST bit set, as a stream error (Section 5.4.2) of type
CONNECT_ERROR.
The same applies to a client-side Upgraded whose local end fails.
Versions: hyper 1.9.0. master (1.11.1) has the same code.
Mechanism
proto::h2::upgrade::pairsplits the stream.H2Upgradedkeeps the
RecvStreamand an mpsc sender. TheSendStreammoves into
UpgradedSendStreamTask, which the executor runs.H2Upgraded::poll_shutdowncloses the channel. DroppingH2Upgradeddrops
the sender, which also closes it.UpgradedSendStreamTask::tickanswers a closed channel with
send_data(SendBuf::None, true), which isEND_STREAM.H2Upgradedispub(super)in the privateprotomodule, so
Upgraded::downcastcannot reach it, and theSendStreamis owned by the
task anyway.
So there is no path from user code to SendStream::send_reset.
Reproduction
- Serve HTTP/2 with hyper and accept a
CONNECT; respond200and await
hyper::upgrade::on(req). - Relay the
Upgradedto a TCP connection, and have the remote end of that
TCP connection reset (for exampleSO_LINGER=0then close). - The relay sees
ECONNRESETand drops theUpgraded. - The h2 client's response body ends with
None(END_STREAM), exactly as it
would after a normal FIN. It never sees an error.
Describe the solution you'd like
A small method on Upgraded that queues RST_STREAM(CONNECT_ERROR) for an
HTTP/2 upgrade and returns whether it did, for example
Upgraded::reset_with_connect_error(&mut self) -> bool. It is a no-op that
returns false for an HTTP/1 upgrade. Internally a oneshot carries the reason
to UpgradedSendStreamTask, which checks it before reading the data channel,
so a reset queued just before a drop still wins over the END_STREAM.
Describe alternatives you've considered
A version that takes any error code (h2::Reason is not public in hyper, so a
u32 or a new hyper type) would also work; CONNECT_ERROR is the code the RFC
names for this case. We carry the patch in a vendored copy and can send a PR.
Additional context
We hit this in an HTTP/2 CONNECT tunnel relay (HBONE) and currently carry the change as a patch on a vendored hyper 1.9.0. Happy to open a PR against master.
- Lingua principale
- Rust
- Stelle
- 16.3k
- Fork
- 1.8k
- Merge medio
- 2g 8h
- PR unite (30g)
- 11
Preparare l'ambiente
- Nessun Dockerfile né file Docker Compose
- Nessun modello di pull request
- Leggi la guida per i contributori
Come iniziare
- Leggi tutta la issue e poi la guida ai contributi del progetto.
- Commenta sulla issue per dire che te ne occupi tu — evita che due persone facciano lo stesso lavoro.
- Fai un fork del repository e lavora su un branch.
- Apri una pull request che faccia riferimento al numero della issue.
Altre issue di hyperium/hyper
-
Difficoltà 2/5 1-3 ore Idoneità per principianti 88/100
hyperium/hyper#4206 · 2 commenti ·
I maintainer di solito rispondono entro 4 giorni
-
C-feature
Difficoltà 1/5 Meno di un'ora Idoneità per principianti 65/100
hyperium/hyper#2652 · 4 reazioni ·
I maintainer di solito rispondono entro 4 giorni
-
Difficoltà 3/5 1-2 giorni Idoneità per principianti 35/100
I maintainer di solito rispondono entro 4 giorni
-
Difficoltà 4/5 3-5 giorni Idoneità per principianti 62/100
I maintainer di solito rispondono entro 4 giorni
-
C-feature
Difficoltà 5/5 Più di una settimana Idoneità per principianti 35/100
hyperium/hyper#4186 · 1 commento ·
I maintainer di solito rispondono entro 4 giorni
Tutte le issue di hyperium/hyper
Issue simili
-
Difficoltà 2/5 1-3 ore Idoneità per principianti 84/100
vercel-labs/agent-browser#2017 ·
I maintainer di solito rispondono entro 1 giorno
-
Difficoltà 2/5 1-3 ore Idoneità per principianti 72/100
tursodatabase/turso#9405 ·
I maintainer di solito rispondono entro 1 giorno
-
bug
Difficoltà 2/5 1-3 ore Idoneità per principianti 72/100
PolyMeilex/Neothesia#447 ·
I maintainer di solito rispondono entro 1 giorno
-
backend::vllm diffusion multimodal
Difficoltà 2/5 1-3 ore Idoneità per principianti 72/100
I maintainer di solito rispondono entro 1 giorno
-
Difficoltà 2/5 1-3 ore Idoneità per principianti 68/100
trezor/trezor-firmware#7985 ·
I maintainer di solito rispondono entro 2 giorni