Hacktoberfest 2026:维护者为十月标记出来的 issue,仍然开放、适合新手。 浏览 Hacktoberfest issue

Upgraded HTTP/2 CONNECT streams cannot be reset, so a failed tunnel looks like a clean close

未关闭
#4,209 0 条评论 0 个 reaction 已指派 0 人 在 GitHub 查看

维护者通常 2 天内回复

还没有人认领这个 Issue。

评估

难度
4/5
预计耗时
3-5 天
新手友好度
55/100
Issue 类型
功能
描述清晰度
基本清楚
活跃度
活跃
技术栈
rust

调研方向

Start with proto::h2::upgrade::pair, H2Upgraded::poll_shutdown, and UpgradedSendStreamTask::tick to trace how shutdown becomes END_STREAM. Then inspect how Upgraded::downcast reaches upgrade implementations. Done means an HTTP/2 CONNECT upgrade can queue CONNECT_ERROR while HTTP/1 upgrades remain unchanged, including the reported tunnel-reset scenario.

由索引模型根据 Issue 内容生成。

描述

Is your feature request related to a problem? Please describe.

A server that accepts an HTTP/2 CONNECT (or extended CONNECT) gets the
tunnel from hyper::upgrade::on as an Upgraded. hyper offers no way to end
that stream with an error. Dropping the Upgraded, or shutting it down, always
sends a clean END_STREAM. A proxy whose tunnelled connection fails therefore
cannot tell the client, and the client cannot tell a failed tunnel from a
complete one.

RFC 9113, section 8.5:

A proxy treats any error in the TCP connection, which includes receiving a
TCP segment with the RST bit set, as a stream error (Section 5.4.2) of type
CONNECT_ERROR.

The same applies to a client-side Upgraded whose local end fails.

Versions: hyper 1.9.0. master (1.11.1) has the same code.

Mechanism
  • proto::h2::upgrade::pair splits the stream. H2Upgraded keeps the
    RecvStream and an mpsc sender. The SendStream moves into
    UpgradedSendStreamTask, which the executor runs.
  • H2Upgraded::poll_shutdown closes the channel. Dropping H2Upgraded drops
    the sender, which also closes it.
  • UpgradedSendStreamTask::tick answers a closed channel with
    send_data(SendBuf::None, true), which is END_STREAM.
  • H2Upgraded is pub(super) in the private proto module, so
    Upgraded::downcast cannot reach it, and the SendStream is owned by the
    task anyway.

So there is no path from user code to SendStream::send_reset.

Reproduction
  1. Serve HTTP/2 with hyper and accept a CONNECT; respond 200 and await
    hyper::upgrade::on(req).
  2. Relay the Upgraded to a TCP connection, and have the remote end of that
    TCP connection reset (for example SO_LINGER=0 then close).
  3. The relay sees ECONNRESET and drops the Upgraded.
  4. The h2 client's response body ends with None (END_STREAM), exactly as it
    would after a normal FIN. It never sees an error.

Describe the solution you'd like

A small method on Upgraded that queues RST_STREAM(CONNECT_ERROR) for an
HTTP/2 upgrade and returns whether it did, for example
Upgraded::reset_with_connect_error(&mut self) -> bool. It is a no-op that
returns false for an HTTP/1 upgrade. Internally a oneshot carries the reason
to UpgradedSendStreamTask, which checks it before reading the data channel,
so a reset queued just before a drop still wins over the END_STREAM.

Describe alternatives you've considered

A version that takes any error code (h2::Reason is not public in hyper, so a
u32 or a new hyper type) would also work; CONNECT_ERROR is the code the RFC
names for this case. We carry the patch in a vendored copy and can send a PR.

Additional context

We hit this in an HTTP/2 CONNECT tunnel relay (HBONE) and currently carry the change as a patch on a vendored hyper 1.9.0. Happy to open a PR against master.

主要语言
Rust
星标
16.3k
派生
1.8k
平均合并
4 天 7 小时
30 天内合并 PR
10

环境准备

  • 没有 Dockerfile 或 Docker Compose 文件
  • 没有 Pull Request 模板
  • 阅读贡献指南

从这里开始

  1. 先读完整个 Issue,再读项目的贡献指南。
  2. 在 Issue 下留言说明你要接手 —— 这能避免两个人做同样的事。
  3. Fork 仓库,在一个分支上完成修改。
  4. 提交 Pull Request,并在描述里引用这个 Issue 编号。

hyperium/hyper 的其他 Issue

查看 hyperium/hyper 的全部 Issue

相似的 Issue

更多 Rust Issue

把新 issue 发到你的邮箱

精选适合新手参与的 GitHub issue 摘要。