Upgraded HTTP/2 CONNECT streams cannot be reset, so a failed tunnel looks like a clean close
维护者通常 2 天内回复
还没有人认领这个 Issue。
评估
- 难度
- 4/5
- 预计耗时
- 3-5 天
- 新手友好度
- 55/100
- Issue 类型
- 功能
- 描述清晰度
- 基本清楚
- 活跃度
- 活跃
- 技术栈
- rust
调研方向
Start with proto::h2::upgrade::pair, H2Upgraded::poll_shutdown, and UpgradedSendStreamTask::tick to trace how shutdown becomes END_STREAM. Then inspect how Upgraded::downcast reaches upgrade implementations. Done means an HTTP/2 CONNECT upgrade can queue CONNECT_ERROR while HTTP/1 upgrades remain unchanged, including the reported tunnel-reset scenario.
由索引模型根据 Issue 内容生成。
描述
Is your feature request related to a problem? Please describe.
A server that accepts an HTTP/2 CONNECT (or extended CONNECT) gets the
tunnel from hyper::upgrade::on as an Upgraded. hyper offers no way to end
that stream with an error. Dropping the Upgraded, or shutting it down, always
sends a clean END_STREAM. A proxy whose tunnelled connection fails therefore
cannot tell the client, and the client cannot tell a failed tunnel from a
complete one.
RFC 9113, section 8.5:
A proxy treats any error in the TCP connection, which includes receiving a
TCP segment with the RST bit set, as a stream error (Section 5.4.2) of type
CONNECT_ERROR.
The same applies to a client-side Upgraded whose local end fails.
Versions: hyper 1.9.0. master (1.11.1) has the same code.
Mechanism
proto::h2::upgrade::pairsplits the stream.H2Upgradedkeeps the
RecvStreamand an mpsc sender. TheSendStreammoves into
UpgradedSendStreamTask, which the executor runs.H2Upgraded::poll_shutdowncloses the channel. DroppingH2Upgradeddrops
the sender, which also closes it.UpgradedSendStreamTask::tickanswers a closed channel with
send_data(SendBuf::None, true), which isEND_STREAM.H2Upgradedispub(super)in the privateprotomodule, so
Upgraded::downcastcannot reach it, and theSendStreamis owned by the
task anyway.
So there is no path from user code to SendStream::send_reset.
Reproduction
- Serve HTTP/2 with hyper and accept a
CONNECT; respond200and await
hyper::upgrade::on(req). - Relay the
Upgradedto a TCP connection, and have the remote end of that
TCP connection reset (for exampleSO_LINGER=0then close). - The relay sees
ECONNRESETand drops theUpgraded. - The h2 client's response body ends with
None(END_STREAM), exactly as it
would after a normal FIN. It never sees an error.
Describe the solution you'd like
A small method on Upgraded that queues RST_STREAM(CONNECT_ERROR) for an
HTTP/2 upgrade and returns whether it did, for example
Upgraded::reset_with_connect_error(&mut self) -> bool. It is a no-op that
returns false for an HTTP/1 upgrade. Internally a oneshot carries the reason
to UpgradedSendStreamTask, which checks it before reading the data channel,
so a reset queued just before a drop still wins over the END_STREAM.
Describe alternatives you've considered
A version that takes any error code (h2::Reason is not public in hyper, so a
u32 or a new hyper type) would also work; CONNECT_ERROR is the code the RFC
names for this case. We carry the patch in a vendored copy and can send a PR.
Additional context
We hit this in an HTTP/2 CONNECT tunnel relay (HBONE) and currently carry the change as a patch on a vendored hyper 1.9.0. Happy to open a PR against master.
- 主要语言
- Rust
- 星标
- 16.3k
- 派生
- 1.8k
- 平均合并
- 4 天 7 小时
- 30 天内合并 PR
- 10
环境准备
- 没有 Dockerfile 或 Docker Compose 文件
- 没有 Pull Request 模板
- 阅读贡献指南
从这里开始
- 先读完整个 Issue,再读项目的贡献指南。
- 在 Issue 下留言说明你要接手 —— 这能避免两个人做同样的事。
- Fork 仓库,在一个分支上完成修改。
- 提交 Pull Request,并在描述里引用这个 Issue 编号。
hyperium/hyper 的其他 Issue
-
C-feature
难度 1/5 1 小时以内 新手友好度 65/100
hyperium/hyper#2652 · 4 个 reaction ·
维护者通常 2 天内回复
-
难度 3/5 1-2 天 新手友好度 74/100
维护者通常 2 天内回复
-
难度 3/5 1-2 天 新手友好度 35/100
维护者通常 2 天内回复
-
难度 4/5 3-5 天 新手友好度 62/100
维护者通常 2 天内回复
-
C-feature
难度 5/5 一周以上 新手友好度 35/100
维护者通常 2 天内回复
相似的 Issue
-
难度 2/5 1-3 小时 新手友好度 88/100
aws-samples/sample-pacer#76 ·
维护者通常 1 天内回复
-
难度 2/5 1-3 小时 新手友好度 68/100
-
难度 2/5 1-3 小时 新手友好度 68/100
-
难度 2/5 1-3 小时 新手友好度 78/100
维护者通常 1 天内回复
-
难度 2/5 1-3 小时 新手友好度 86/100
axodotdev/cargo-dist#2523 ·
维护者通常 2 天内回复