Upgraded HTTP/2 CONNECT streams cannot be reset, so a failed tunnel looks like a clean close
Maintainers usually reply within 2 days
Nobody has claimed this yet.
Assessment
- Difficulty
- 4/5
- Estimated time
- 3-5 days
- Newbie friendliness
- 55/100
- Issue type
- Feature
- Clarity
- Mostly clear
- Activity status
- Active
- Tech stack
- rust
- Domain
- backend-api-design, networking
Research direction
Start with proto::h2::upgrade::pair, H2Upgraded::poll_shutdown, and UpgradedSendStreamTask::tick to trace how shutdown becomes END_STREAM. Then inspect how Upgraded::downcast reaches upgrade implementations. Done means an HTTP/2 CONNECT upgrade can queue CONNECT_ERROR while HTTP/1 upgrades remain unchanged, including the reported tunnel-reset scenario.
Written by the indexing model from the issue text.
Description
Is your feature request related to a problem? Please describe.
A server that accepts an HTTP/2 CONNECT (or extended CONNECT) gets the
tunnel from hyper::upgrade::on as an Upgraded. hyper offers no way to end
that stream with an error. Dropping the Upgraded, or shutting it down, always
sends a clean END_STREAM. A proxy whose tunnelled connection fails therefore
cannot tell the client, and the client cannot tell a failed tunnel from a
complete one.
RFC 9113, section 8.5:
A proxy treats any error in the TCP connection, which includes receiving a
TCP segment with the RST bit set, as a stream error (Section 5.4.2) of type
CONNECT_ERROR.
The same applies to a client-side Upgraded whose local end fails.
Versions: hyper 1.9.0. master (1.11.1) has the same code.
Mechanism
proto::h2::upgrade::pairsplits the stream.H2Upgradedkeeps the
RecvStreamand an mpsc sender. TheSendStreammoves into
UpgradedSendStreamTask, which the executor runs.H2Upgraded::poll_shutdowncloses the channel. DroppingH2Upgradeddrops
the sender, which also closes it.UpgradedSendStreamTask::tickanswers a closed channel with
send_data(SendBuf::None, true), which isEND_STREAM.H2Upgradedispub(super)in the privateprotomodule, so
Upgraded::downcastcannot reach it, and theSendStreamis owned by the
task anyway.
So there is no path from user code to SendStream::send_reset.
Reproduction
- Serve HTTP/2 with hyper and accept a
CONNECT; respond200and await
hyper::upgrade::on(req). - Relay the
Upgradedto a TCP connection, and have the remote end of that
TCP connection reset (for exampleSO_LINGER=0then close). - The relay sees
ECONNRESETand drops theUpgraded. - The h2 client's response body ends with
None(END_STREAM), exactly as it
would after a normal FIN. It never sees an error.
Describe the solution you'd like
A small method on Upgraded that queues RST_STREAM(CONNECT_ERROR) for an
HTTP/2 upgrade and returns whether it did, for example
Upgraded::reset_with_connect_error(&mut self) -> bool. It is a no-op that
returns false for an HTTP/1 upgrade. Internally a oneshot carries the reason
to UpgradedSendStreamTask, which checks it before reading the data channel,
so a reset queued just before a drop still wins over the END_STREAM.
Describe alternatives you've considered
A version that takes any error code (h2::Reason is not public in hyper, so a
u32 or a new hyper type) would also work; CONNECT_ERROR is the code the RFC
names for this case. We carry the patch in a vendored copy and can send a PR.
Additional context
We hit this in an HTTP/2 CONNECT tunnel relay (HBONE) and currently carry the change as a patch on a vendored hyper 1.9.0. Happy to open a PR against master.
- Dominant language
- Rust
- Stars
- 16.3k
- Forks
- 1.8k
- Avg merge
- 2d 13h
- Merged PRs (30d)
- 10
Getting set up
- No Dockerfile or Docker Compose file
- No pull request template
- Read the contributing guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from hyperium/hyper
-
Difficulty 2/5 1-3 hours Newbie friendliness 88/100
hyperium/hyper#4206 · 2 comments ·
Maintainers usually reply within 2 days
-
C-feature
Difficulty 1/5 Under an hour Newbie friendliness 65/100
hyperium/hyper#2652 · 4 reactions ·
Maintainers usually reply within 2 days
-
Difficulty 3/5 1-2 days Newbie friendliness 35/100
Maintainers usually reply within 2 days
-
Difficulty 4/5 3-5 days Newbie friendliness 62/100
Maintainers usually reply within 2 days
-
C-feature
Difficulty 5/5 Over a week Newbie friendliness 35/100
hyperium/hyper#4186 · 1 comment ·
Maintainers usually reply within 2 days
Similar issues
-
Difficulty 2/5 1-3 hours Newbie friendliness 68/100
trezor/trezor-firmware#7997 ·
Maintainers usually reply within 2 days
-
Difficulty 1/5 Under an hour Newbie friendliness 88/100
Maintainers usually reply within 1 day
-
Difficulty 2/5 1-3 hours Newbie friendliness 84/100
oxidecomputer/management-gateway-service#506 · 1 comment ·
-
Difficulty 2/5 1-3 hours Newbie friendliness 72/100
scylladb/nodejs-rs-driver#566 ·
Maintainers usually reply within 1 day
-
A-ABI needs-triage relnotes relnotes-needs-review relnotes-tracking-issue T-lang T-libs T-opsem
Difficulty 2/5 1-3 hours Newbie friendliness 68/100
Maintainers usually reply within 1 day