[Bug]: TagBatch reuses a cached PlcReadRequest bound to a closed connection, so fetches fail after the first and never recover after a PLC restart
Los mantenedores suelen responder en 1 día
@chrisdutz ya está trabajando en esto.
Desde el 26/10/2026.
Evaluación
- Dificultad
- 3/5
- Tiempo estimado
- 1-2 días
- Aptitud para principiantes
- 72/100
- Tipo de issue
- Error
- Claridad
- Bien especificado
- Estado de actividad
- Activo
- Stack tecnológico
- java
- Área
- embedded-iot, networking
Línea de trabajo
Read plc4j/tools/event-pump/src/main/java/org/apache/plc4x/java/tools/eventpump/TagBatch.java, focusing on fetchTags(), request caching, connection closing, and invalidateCache(). Reproduce with the issue's TagBatch example using DefaultPlcDriverManager, then repeat with PlcConnectionCache and restart the Modbus simulator. Done means later fetches use the current connection and continue after a PLC restart; add or update event-pump tests covering repeated fetches and recovery.
Escrito por el modelo de indexación a partir del texto del issue.
Descripción
What happened?
TagBatch in plc4j-tools-event-pump builds its PlcReadRequest once and caches it (keyed only on the tag snapshot), but it obtains a connection from the configured PlcConnectionFactory on every fetch and closes that connection after the fetch. A PlcReadRequest is bound to the connection whose builder created it (DefaultPlcReadRequest keeps the PlcReader; execute() calls reader.read(this)), so the cached request keeps targeting the connection of the first fetch. Once that connection is closed, every later fetch fails without ever using the connection that was just opened for it.
Observed against a Modbus TCP simulator (oitc/modbus-server, Docker) with plc4j-tools-event-pump 1.0.0, plc4j-driver-modbus 1.0.0, TimerTrigger(100 ms), three tags (coil:1, holding-register:1:INT, holding-register:2:INT):
DefaultPlcDriverManageras connection factory (a new connection per fetch): fetch 1 succeeds, fetch 2 and every later attempt fail immediately withPlcRuntimeException: Failed to send request, root causeTransportException: Transport is closedatTcpTransportInstance.ensureOpen(TcpTransportInstance.java:319). Each attempt still logs "Modbus TCP connection established" for a connection that is never used. In 5 s: 1 fetch, 3 errors, back-off 1 s, 2 s, 4 s.PlcConnectionCacheas connection factory (one physical connection, a lease per fetch): 49 fetches in 5 s while the simulator is up. Afterdocker stop/docker startof the simulator the batch never recovers: 0 fetches in the following 65 s, every attempt fails withTransport is closed, and no "Connection refused" ever appears because the network is never touched. Even after the cache's idle validation detected the dead connection and opened a new one (at about +58 s), the next fetch failed again: the cached request still targets the old connection.
Cause, same on develop as in 1.0.0 (plc4j/tools/event-pump/src/main/java/org/apache/plc4x/java/tools/eventpump/TagBatch.java):
fetchTags()callsconnectionFactory.getConnection(connectionString)per fetch (line 516) and closes the connection in the completion handler (lines 604 and 621).- The read request is cached in
cachedReadRequest/cachedTagSnapshot(lines 122-123) and reused whenever the tag snapshot is unchanged (lines 529-541). invalidateCache()(lines 712-715) is private and is only called byaddTag(s)/removeTag(s)/clearTags, never on a fetch error or on a different connection.
Expected: a fetch executes its read request on the connection it obtained for that fetch, so a batch over DefaultPlcDriverManager keeps working and a batch over PlcConnectionCache recovers once the PLC is reachable again (the back-off then does its job instead of retrying a dead request forever).
Possible fixes, in order of simplicity: build the request on the connection of the current fetch (the PlcReadRequest.Builder cost is small compared to a network round trip); or cache the request per connection instance; or at least call invalidateCache() on every fetch error.
Workaround we verified: calling removeTag(name) + addTag(name, address) from TagBatchListener.onError forces a rebuild; with PlcConnectionCache the batch then recovers after a simulator restart (275 fetches in the 30 s after docker start, 3 errors in total). Side effect: the tag order in later responses changes.
Reproduction (JDK 21, plc4j-api, plc4j-tools-event-pump, plc4j-driver-modbus 1.0.0 on the classpath; docker run -d -p 127.0.0.1:5020:5020 oitc/modbus-server:latest):
TagBatch batch = TagBatch.builder()
.withBatchId("repro")
.withConnectionFactory(new DefaultPlcDriverManager())
.withConnectionString("modbus-tcp://127.0.0.1:5020")
.addTagAddress("c1", "coil:1")
.withTrigger(new TimerTrigger(100, TimeUnit.MILLISECONDS))
.withListener(new TagBatchListener() {
@Override
public void onTagsFetched(TagBatch b, PlcReadResponse r) {
System.out.println("fetched " + r.getResponseCode("c1"));
}
@Override
public void onError(TagBatch b, Throwable t) {
System.out.println("error " + t);
}
})
.build();
batch.start();
Thread.sleep(5000);
batch.close();
Output: one fetched OK, then only error ... Transport is closed lines. Replace the factory with PlcConnectionCache.getBuilder().withConnectionFactory(new DefaultPlcDriverManager()).build(), restart the simulator while the batch runs, and the error lines never stop.
Found while porting Apache Camel's camel-plc4x triggered consumer from plc4j-scraper to the event pump (CAMEL-25617).
Version
v1.0.0 (code unchanged on develop as of 2026-10-23)
Programming Languages
- plc4c
- plc4go
- plc4j
- plc4net
- plc4py
Protocols
- Modbus (used for the reproduction; the cause is protocol-independent)
- Lenguaje dominante
- Java
- Estrellas
- 1.8k
- Forks
- 514
- Merge medio
- 2 d 2 h
- PR fusionados (30 d)
- 34
Preparar el entorno
- Incluye un Dockerfile o un archivo de Docker Compose
- Tiene una plantilla de pull request
- Leer la guía de contribución
Primeros pasos
- Lee el issue completo y luego la guía de contribución del proyecto.
- Comenta en el issue que vas a ocuparte — evita que dos personas hagan lo mismo.
- Haz un fork del repositorio y trabaja en una rama.
- Abre un pull request que haga referencia al número del issue.
Más de apache/plc4x
-
[Bug]: eip.mspec formationAbiertoEthernet/IP java
Dificultad 1/5 Menos de una hora Aptitud para principiantes 90/100
apache/plc4x#2733 · 5 comentarios ·
Los mantenedores suelen responder en 1 día
-
[Bug]: [Modbus] Support UDINT with least significant register first (little-endian word order)Abierto
Dificultad 4/5 3-5 días Aptitud para principiantes 52/100
Los mantenedores suelen responder en 1 día
-
Dificultad 4/5 3-5 días Aptitud para principiantes 45/100
Los mantenedores suelen responder en 1 día
-
[Bug]: OPC-UA driver 1.0.0 fails against a certificate-less server even with security-policy=NONE (regression vs 0.13.1)Posiblemente ocupada @splatch la tomó hace 9 días. Abierto
apache/plc4x#2830 · 1 asignado ·
Los mantenedores suelen responder en 1 día
-
[Bug]: OPC UA UserNameIdentityToken sends length+password+nonce instead of the plain password when token security policy is NonePosiblemente ocupada @splatch la tomó hace 29 días. AbiertoOPC-UA
apache/plc4x#2791 · 2 comentarios · 2 asignados ·
Los mantenedores suelen responder en 1 día
Todos los issues de apache/plc4x
Issues similares
-
Dificultad 2/5 1-3 horas Aptitud para principiantes 82/100
Los mantenedores suelen responder en 1 día
-
Dificultad 1/5 Menos de una hora Aptitud para principiantes 88/100
quarkusio/quarkus-agent-mcp#302 ·
Los mantenedores suelen responder en 2 días
-
build
Dificultad 1/5 Menos de una hora Aptitud para principiantes 85/100
MetricsHub/metricshub-community#1472 ·
Los mantenedores suelen responder en 1 día
-
Dificultad 2/5 1-3 horas Aptitud para principiantes 82/100
Los mantenedores suelen responder en 1 día
-
IdentityArrayObjectSet iterator remove may throw ArrayIndexOutOfBoundsExceptionPosiblemente ocupada @jiteshkhatri11 la tomó hoy. Abierto
Dificultad 2/5 1-3 horas Aptitud para principiantes 72/100
javapathfinder/jpf-core#660 · 1 comentario ·