[Bug]: [Modbus] Support UDINT with least significant register first (little-endian word order)
Los mantenedores suelen responder en 1 día
Nadie ha tomado este issue todavía.
Evaluación
- Dificultad
- 4/5
- Tiempo estimado
- 3-5 días
- Aptitud para principiantes
- 52/100
- Tipo de issue
- Nueva funcionalidad
- Claridad
- Bastante claro
- Estado de actividad
- Activo
- Stack tecnológico
- java
- Área
- backend, embedded-iot
Línea de trabajo
Start by reading the PLC4J Modbus tag decoding and payload byte-order code; the issue does not name specific files or tests. Check how UDINT currently handles two holding registers and whether byte order can be separated from register order. Done means a documented way to select least-significant-register-first produces 1431377 for the reported register values.
Escrito por el modelo de indexación a partir del texto del issue.
Descripción
What happened?
I would like to request support for decoding 32-bit unsigned integer values (UDINT) from Modbus holding registers when the least significant 16-bit register is transmitted first.
My Modbus energy meter exposes a 32-bit unsigned energy value across two consecutive holding registers. The meter returns the least significant register first, followed by the most significant register.
I can read both registers successfully using the UINT data type and manually reconstruct the 32-bit value. However, I have not been able to obtain the expected result directly using UDINT with LITTLE_ENDIAN.
Environment
Protocol: Modbus TCP
Driver: Apache PLC4X Modbus TCP
Device: Modbus energy meter
Unit Identifier: 19
Request timeout: 5000 ms
Default payload byte order: BIG_ENDIAN
Connection URL
String connectionUrl =
"modbus-tcp:tcp://10.10.121.55:502"
+ "?unit-identifier=19"
+ "&request-timeout=5000"
+ "&default-payload-byte-order=BIG_ENDIAN";
Steps to Reproduce
- Read the two holding registers as UINT
PlcReadRequest request = connection.readRequestBuilder()
.addTagAddress(
"energy",
"holding-register:29[0..1]:UINT{unit-id: 19}"
)
.build();
The response contains:
response = [55121, 21]
Tag: energy
Response code for energy: OK
The two 16-bit register values are:
First register: 55121
Second register: 21
- Reconstruct the unsigned 32-bit value manually
The expected result is calculated by placing the second register in the upper 16 bits and the first register in the lower 16 bits:
long energyValue =
((long) 21 << 16) | 55121L;
Result:
Assembled Energy Value: 1431377
This produces the expected energy value.
- Attempt to read the value directly as UDINT
I am unable to obtain the same expected value by reading the two registers directly as UDINT with LITTLE_ENDIAN byte order.
I would like PLC4X to support decoding this register arrangement directly, without requiring applications to read individual registers and reconstruct the value manually.
Expected Behavior
PLC4X should support decoding a 32-bit unsigned integer from two Modbus holding registers when the least significant register is first.
For the example above:
Register 1 (LSW) = 55121
Register 2 (MSW) = 21
Expected UDINT value = 1431377
The driver should provide a documented and supported way to select the register/word order independently of the byte order within each 16-bit register, where necessary.
Actual Behavior
The two registers can be read successfully as UINT, and the expected value can be calculated manually.
However, I cannot obtain the expected result directly using UDINT with LITTLE_ENDIAN.
Requested Enhancement
Please clarify whether the Modbus driver supports 32-bit unsigned integer decoding with least significant register first.
If this arrangement is not currently supported, please consider adding support for configurable 16-bit register/word ordering for multi-register data types such as:
UDINT — unsigned 32-bit integer
DINT — signed 32-bit integer
REAL — 32-bit floating-point value
Other supported multi-register data types, where applicable
The configuration should distinguish between:
Byte order: the ordering of bytes within an individual 16-bit register.
Word/register order: the ordering of the two 16-bit registers that make up a 32-bit value.
These settings should be independently configurable where the protocol and driver implementation permit it.
Additional Information
The Modbus connection and read request are successful, and the response code is OK.
The issue concerns decoding the two register values into the expected 32-bit unsigned integer rather than reading the registers themselves.
Version
v1.0.0
Programming Languages
- plc4c
- plc4go
- plc4j
- plc4net
- plc4py
Protocols
- AB-Ethernet
- ADS /AMS
- BACnet/IP
- C-Bus
- CANopen
- EtherNet/IP
- Firmata
- IEC-69870
- KNXnet/IP
- Modbus
- OPC-UA
- PLC4X
- Profinet
- S7
- Simulated
- SLMP
- UMAS
- Lenguaje dominante
- Java
- Estrellas
- 1.8k
- Forks
- 512
- Merge medio
- 2 d 2 h
- PR fusionados (30 d)
- 34
Preparar el entorno
- Incluye un Dockerfile o un archivo de Docker Compose
- Tiene una plantilla de pull request
- Leer la guía de contribución
Primeros pasos
- Lee el issue completo y luego la guía de contribución del proyecto.
- Comenta en el issue que vas a ocuparte — evita que dos personas hagan lo mismo.
- Haz un fork del repositorio y trabaja en una rama.
- Abre un pull request que haga referencia al número del issue.
Más de apache/plc4x
-
[Bug]: eip.mspec formationAbiertoEthernet/IP java
Dificultad 1/5 Menos de una hora Aptitud para principiantes 90/100
apache/plc4x#2733 · 5 comentarios ·
Los mantenedores suelen responder en 1 día
-
Dificultad 4/5 3-5 días Aptitud para principiantes 45/100
Los mantenedores suelen responder en 1 día
-
[Bug]: TagBatch reuses a cached PlcReadRequest bound to a closed connection, so fetches fail after the first and never recover after a PLC restartPosiblemente ocupada @chrisdutz la tomó hace 3 días. Abierto
Dificultad 3/5 1-2 días Aptitud para principiantes 72/100
apache/plc4x#2832 · 1 asignado ·
Los mantenedores suelen responder en 1 día
-
[Bug]: OPC-UA driver 1.0.0 fails against a certificate-less server even with security-policy=NONE (regression vs 0.13.1)Posiblemente ocupada @splatch la tomó hace 8 días. Abierto
apache/plc4x#2830 · 1 asignado ·
Los mantenedores suelen responder en 1 día
-
[Bug]: OPC UA UserNameIdentityToken sends length+password+nonce instead of the plain password when token security policy is NonePosiblemente ocupada @splatch la tomó hace 27 días. AbiertoOPC-UA
apache/plc4x#2791 · 2 comentarios · 2 asignados ·
Los mantenedores suelen responder en 1 día
Todos los issues de apache/plc4x
Issues similares
-
area:core bug priority:p2
Dificultad 2/5 1-3 horas Aptitud para principiantes 82/100
aomarai/minecraft-mcp#247 ·
Los mantenedores suelen responder en 1 día
-
help wanted
Dificultad 2/5 1-3 horas Aptitud para principiantes 68/100
antonyrag/ragleap-core#1062 ·
-
Dificultad 2/5 1-3 horas Aptitud para principiantes 66/100
Vakore/ZappierGames#232 ·
-
Dificultad 2/5 1-3 horas Aptitud para principiantes 83/100
-
bug
Dificultad 2/5 1-3 horas Aptitud para principiantes 64/100
constellation-app/constellation#2588 ·