Exact package ID resolved to another project's uninstaller (DORON177.BatteryHub)
Maintainer antworten meist innerhalb von 2 Tagen
Dieses Issue hat noch niemand übernommen.
Bewertung
- Schwierigkeit
- 5/5
- Geschätzter Aufwand
- Über eine Woche
- Anfängerfreundlichkeit
- 35/100
- Issue-Typ
- Bug
- Klarheit
- Größtenteils klar
- Aktivitätsstatus
- Aktiv
- Tech-Stack
- cpp
- Bereich
- backend-api-design, cli, security
Rechercherichtung
Start with the linked matching code in src/AppInstallerRepositoryCore/CompositeSource.cpp at lines 74–99 and trace how the installed application is associated with the catalog entry during winget uninstall. The report says the retained logs do not identify which field decided the match, so first determine whether the association can distinguish heuristic matches from verified installations. Done means confirming the resolution path and addressing the risk that an exact-ID uninstall selects another project's uninstaller.
Vom Indexierungsmodell aus dem Issue-Text verfasst.
Beschreibung
Relevant area(s)
WinGet CLI, COM API
Relevant command(s)
winget uninstall
Brief description of your issue
On 26 November 2026, WinGet resolved DORON177.BatteryHub to BatteryHub 1.1.0 from krisgfx9/Wireless-Device-Battery-Monitor. These are different projects. An exact-ID uninstall launched the original project's uninstaller and removed it.
| Installed application | Catalog candidate | |
|---|---|---|
| Name | BatteryHub | Battery Hub |
| Publisher in installer or Apps & Features metadata | BatteryHub contributors | Battery Hub contributors |
| Installer | Inno Setup, version 1.1.0 | Nullsoft/NSIS, version 2.0.7 |
| Identifier | Inno AppId {7E0B5C2A-3F4D-4C8E-9B61-2D5A8F1C4E93} |
ProductCode 3dbe5c54-f0bc-5ecd-8ed5-c18e28514bdd |
Steps to reproduce
Sequence observed on the affected PC. I have not repeated the uninstall on a fresh system.
- The standalone krisgfx9 BatteryHub 1.1.0 was installed. Its installer embeds
/repos/krisgfx9/Wireless-Device-Battery-Monitor/releases/latestas its update path. - UniGetUI queried the WinGet COM API. WinGet retrieved the catalog entry for
DORON177.BatteryHub, and UniGetUI offered 2.0.7 as an update to 1.1.0. - UniGetUI requested an uninstall with
--id DORON177.BatteryHub --exact --source winget --version 1.1.0. WinGet reported one matching app and startedC:\Program Files\BatteryHub\unins000.exewith/SILENT. The uninstall succeeded.
Expected behavior
An exact catalog ID should not select another project's uninstaller. If the association cannot be verified, leave the installed application in place and require the caller to identify the local installation explicitly.
Actual behavior
WinGet removed the krisgfx9 application. UniGetUI then issued a separate install for DORON177.BatteryHub 2.0.7, which succeeded.
In the catalog snapshot used during the incident, only DORON177.BatteryHub had the normalized pair batteryhub / batteryhubcontributors. Its only product code was the NSIS code above. The original Inno GUID had no product-code entry in the snapshot. A name/publisher collision is the likely explanation. The retained logs do not identify which field decided the match.
Could you confirm how this association was resolved and whether the uninstall path can distinguish a heuristic match from a verified installation? Matching code in 1.29.380 · 2.0.7 installer manifest
Related: #3072 concerns an incorrect ID in the installed list. In this case the association reached the uninstall step.
Environment
Windows 11 Pro 26H2 x64, build 26300.10075
WinGet 1.29.380 / Microsoft.DesktopAppInstaller 1.29.380.0
Source: winget, catalog snapshot 2026.1126.1714.44
Discovery: UniGetUI 2026.3.4 via the WinGet COM API
Uninstall: winget.exe
- Vorherrschende Sprache
- C++
- Sterne
- 26.6k
- Forks
- 1.8k
- Ø Merge
- 2 T. 18 Std.
- Gemergte PRs (30 T.)
- 42
Entwicklungsumgebung
- Kein Dockerfile und keine Docker-Compose-Datei
- Hat eine Pull-Request-Vorlage
- Beitragsleitfaden lesen
Erste Schritte
- Lesen Sie das ganze Issue und danach den Beitragsleitfaden des Projekts.
- Schreiben Sie ins Issue, dass Sie es übernehmen — das erspart doppelte Arbeit.
- Forken Sie das Repository und arbeiten Sie in einem Branch.
- Öffnen Sie einen Pull Request, der die Issue-Nummer nennt.
Mehr aus microsoft/winget-cli
-
Command-Install Needs-Triage
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 79/100
microsoft/winget-cli#6718 ·
Maintainer antworten meist innerhalb von 2 Tagen
-
Issue-Docs Needs-Triage
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 70/100
microsoft/winget-cli#6692 ·
Maintainer antworten meist innerhalb von 2 Tagen
-
Issue-Docs Possible-Duplicate
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 76/100
microsoft/winget-cli#6493 · 1 Kommentar ·
Maintainer antworten meist innerhalb von 2 Tagen
-
Issue-Feature
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 68/100
microsoft/winget-cli#6427 ·
Maintainer antworten meist innerhalb von 2 Tagen
-
Issue-Docs msstore
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 64/100
microsoft/winget-cli#6331 · 1 Kommentar ·
Maintainer antworten meist innerhalb von 2 Tagen
Alle Issues in microsoft/winget-cli
Ähnliche Issues
-
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 72/100
cp-algorithms/cp-algorithms#1774 ·
Maintainer antworten meist innerhalb von 1 Tag
-
bug
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 84/100
telefonicaid/fiware-orion#4836 ·
Maintainer antworten meist innerhalb von 1 Tag
-
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 78/100
SanderMertens/flecs#2463 ·
Maintainer antworten meist innerhalb von 1 Tag
-
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 79/100
Maintainer antworten meist innerhalb von 2 Tagen
-
nixd exits at startup when its parent process belongs to another userEvtl. vergeben @conao3 hat das heute übernommen. Offen
Schwierigkeit 2/5 1-3 Stunden Anfängerfreundlichkeit 78/100
nix-community/nixd#930 ·
Maintainer antworten meist innerhalb von 2 Tagen