Exact package ID resolved to another project's uninstaller (DORON177.BatteryHub)

オープン
#6,716 コメント 0 件 リアクション 0 件 担当者 0 名 GitHub で見る

メンテナーはふだん 2 日以内に返信

まだ誰も着手していません。

評価

難易度
5/5
見積もり時間
1週間以上
初心者へのやさしさ
35/100
issue の種類
バグ
明瞭さ
おおむね明確
活発さ
活発
技術スタック
cpp

調査の方向性

Start with the linked matching code in src/AppInstallerRepositoryCore/CompositeSource.cpp at lines 74–99 and trace how the installed application is associated with the catalog entry during winget uninstall. The report says the retained logs do not identify which field decided the match, so first determine whether the association can distinguish heuristic matches from verified installations. Done means confirming the resolution path and addressing the risk that an exact-ID uninstall selects another project's uninstaller.

索引モデルが issue の本文から書いたものです。

説明

Area-COM-API Command-Uninstall Issue-Bug Needs-Triage
Relevant area(s)

WinGet CLI, COM API

Relevant command(s)

winget uninstall

Brief description of your issue

On 26 November 2026, WinGet resolved DORON177.BatteryHub to BatteryHub 1.1.0 from krisgfx9/Wireless-Device-Battery-Monitor. These are different projects. An exact-ID uninstall launched the original project's uninstaller and removed it.

Installed application Catalog candidate
Name BatteryHub Battery Hub
Publisher in installer or Apps & Features metadata BatteryHub contributors Battery Hub contributors
Installer Inno Setup, version 1.1.0 Nullsoft/NSIS, version 2.0.7
Identifier Inno AppId {7E0B5C2A-3F4D-4C8E-9B61-2D5A8F1C4E93} ProductCode 3dbe5c54-f0bc-5ecd-8ed5-c18e28514bdd
Steps to reproduce

Sequence observed on the affected PC. I have not repeated the uninstall on a fresh system.

  1. The standalone krisgfx9 BatteryHub 1.1.0 was installed. Its installer embeds /repos/krisgfx9/Wireless-Device-Battery-Monitor/releases/latest as its update path.
  2. UniGetUI queried the WinGet COM API. WinGet retrieved the catalog entry for DORON177.BatteryHub, and UniGetUI offered 2.0.7 as an update to 1.1.0.
  3. UniGetUI requested an uninstall with --id DORON177.BatteryHub --exact --source winget --version 1.1.0. WinGet reported one matching app and started C:\Program Files\BatteryHub\unins000.exe with /SILENT. The uninstall succeeded.
Expected behavior

An exact catalog ID should not select another project's uninstaller. If the association cannot be verified, leave the installed application in place and require the caller to identify the local installation explicitly.

Actual behavior

WinGet removed the krisgfx9 application. UniGetUI then issued a separate install for DORON177.BatteryHub 2.0.7, which succeeded.

In the catalog snapshot used during the incident, only DORON177.BatteryHub had the normalized pair batteryhub / batteryhubcontributors. Its only product code was the NSIS code above. The original Inno GUID had no product-code entry in the snapshot. A name/publisher collision is the likely explanation. The retained logs do not identify which field decided the match.

Could you confirm how this association was resolved and whether the uninstall path can distinguish a heuristic match from a verified installation? Matching code in 1.29.380 · 2.0.7 installer manifest

Related: #3072 concerns an incorrect ID in the installed list. In this case the association reached the uninstall step.

Environment
Windows 11 Pro 26H2 x64, build 26300.10075
WinGet 1.29.380 / Microsoft.DesktopAppInstaller 1.29.380.0
Source: winget, catalog snapshot 2026.1126.1714.44
Discovery: UniGetUI 2026.3.4 via the WinGet COM API
Uninstall: winget.exe
主要言語
C++
スター
26.6k
フォーク
1.8k
平均マージ
2日 18時間
マージ済み PR(30日)
42

環境構築

はじめの一歩

  1. issue を最後まで読み、次にプロジェクトのコントリビューションガイドを読みます。
  2. 着手することを issue にコメントします — 二人が同じ作業をするのを防げます。
  3. リポジトリをフォークし、ブランチを切って変更します。
  4. issue 番号を参照したプルリクエストを送ります。

microsoft/winget-cli のほかの issue

microsoft/winget-cli の issue をすべて見る

似ている issue

C++ の issue をもっと見る

新しい issue をメールで受け取る

初心者向けの GitHub issue を短くまとめたダイジェスト。