Log reads can fail with Errno::EACCES during LogDevice rotation on Windows

未关闭
#188 0 条评论 0 个 reaction 已指派 0 人 在 GitHub 查看

还没有人认领这个 Issue。

评估

难度
4/5
预计耗时
3-5 天
新手友好度
48/100
Issue 类型
缺陷
描述清晰度
基本清楚
活跃度
活跃
技术栈
ruby
领域
backend

调研方向

Start with LogDevice#lock_shift_log and the Windows locking change in commit 7b6146f; the reproduction in the issue shows how a separate reader fails during rotation. Compare the locking behavior with create_logfile and the referenced draft PR fluent/fluentd#5690. Done means choosing and implementing a locking approach that allows reads during rotation while keeping rotators mutually exclusive, then verifying the reproduction on Windows.

由索引模型根据 Issue 内容生成。

描述

Since logger 1.6.3, a read through a separate handle can fail with Errno::EACCES during log rotation on Windows. Commit 7b6146f enabled flock(File::LOCK_EX) in LogDevice#lock_shift_log on Windows. Ruby implements flock there with LockFileEx. The lock is mandatory and covers the whole file.

For example, when Fluentd tails its own log, a read during rotation sometimes fails with Permission denied @ io_getpartial. Fluentd then loses the lines it has not yet read.

Reproduction

The hook makes the read happen at the same point in rotation on every run. In the affected versions, lock_shift_log already holds the lock at that point. A polling reader can hit the same window by chance.

require "logger"
require "tmpdir"

Dir.mktmpdir do |dir|
  path = File.join(dir, "app.log")
  logger = Logger.new(path, 3, 1024)
  logger.info("x" * 1024)

  # Open a separate handle to simulate a program that tails the log.
  reader = File.open(path, File::RDONLY | File::BINARY | File::SHARE_DELETE)

  # Read at the start of shift_log_age, then let rotation continue.
  result = nil
  hook = Module.new do
    private

    define_method(:shift_log_age) do
      begin
        result = "read #{reader.read.bytesize} bytes"
      rescue Errno::EACCES => e
        result = "#{e.class}: #{e.message}"
      end
      super()
    end
  end
  logger.instance_variable_get(:@logdev).singleton_class.prepend(hook)
  logger.info("rotate")

  puts "logger #{Logger::VERSION}: #{result}"
  reader.close
  logger.close
end

Output on Windows 10 (ruby 3.4.13 x64-mingw-ucrt):

logger 1.6.2: read 1143 bytes
logger 1.6.3: Errno::EACCES: Permission denied @ io_fread - .../app.log
logger 1.7.0: Errno::EACCES: Permission denied @ io_fread - .../app.log
Possible fix

One option on Windows is to use LockFileEx to lock a single byte far beyond EOF. Windows allows this, and reads of the log data do not overlap that byte. Rotators that lock the same byte would still wait for each other. A whole-file flock from logger 1.6.3 to 1.7.0 also covers that byte, so mixed versions would still exclude each other. Raymond Chen describes this technique in You can use a file as a synchronization object, too.

The draft PR fluent/fluentd#5690 tries this approach. It overrides lock_shift_log and calls LockFileEx through Fiddle. If you prefer not to call a Win32 API from logger, could the locking step be made overridable?

Related behavior

create_logfile also holds flock(File::LOCK_EX) while writing a new log header. It holds the lock for much less time. Older versions also lock the file here.

#165 is another Windows problem around lock_shift_log after logger 1.6.2.

主要语言
Ruby
星标
161
派生
76
平均合并
2 天 5 小时
30 天内合并 PR
3

环境准备

这个项目没有提供开发容器、Dockerfile 或贡献指南,环境需要你自己搭建:先看它的 README,通用步骤见我们的新手贡献指南。

从这里开始

  1. 先读完整个 Issue,再读项目的贡献指南。
  2. 在 Issue 下留言说明你要接手 —— 这能避免两个人做同样的事。
  3. Fork 仓库,在一个分支上完成修改。
  4. 提交 Pull Request,并在描述里引用这个 Issue 编号。

ruby/logger 的其他 Issue

查看 ruby/logger 的全部 Issue

相似的 Issue

更多 Ruby Issue

把新 issue 发到你的邮箱

精选适合新手参与的 GitHub issue 摘要。