Log reads can fail with Errno::EACCES during LogDevice rotation on Windows
Ninguém assumiu esta issue ainda.
Avaliação
- Dificuldade
- 4/5
- Tempo estimado
- 3-5 dias
- Facilidade para iniciantes
- 48/100
Direção de pesquisa
Start with LogDevice#lock_shift_log and the Windows locking change in commit 7b6146f; the reproduction in the issue shows how a separate reader fails during rotation. Compare the locking behavior with create_logfile and the referenced draft PR fluent/fluentd#5690. Done means choosing and implementing a locking approach that allows reads during rotation while keeping rotators mutually exclusive, then verifying the reproduction on Windows.
Escrita pelo modelo de indexação a partir do texto da issue.
Descrição
Since logger 1.6.3, a read through a separate handle can fail with Errno::EACCES during log rotation on Windows. Commit 7b6146f enabled flock(File::LOCK_EX) in LogDevice#lock_shift_log on Windows. Ruby implements flock there with LockFileEx. The lock is mandatory and covers the whole file.
For example, when Fluentd tails its own log, a read during rotation sometimes fails with Permission denied @ io_getpartial. Fluentd then loses the lines it has not yet read.
Reproduction
The hook makes the read happen at the same point in rotation on every run. In the affected versions, lock_shift_log already holds the lock at that point. A polling reader can hit the same window by chance.
require "logger"
require "tmpdir"
Dir.mktmpdir do |dir|
path = File.join(dir, "app.log")
logger = Logger.new(path, 3, 1024)
logger.info("x" * 1024)
# Open a separate handle to simulate a program that tails the log.
reader = File.open(path, File::RDONLY | File::BINARY | File::SHARE_DELETE)
# Read at the start of shift_log_age, then let rotation continue.
result = nil
hook = Module.new do
private
define_method(:shift_log_age) do
begin
result = "read #{reader.read.bytesize} bytes"
rescue Errno::EACCES => e
result = "#{e.class}: #{e.message}"
end
super()
end
end
logger.instance_variable_get(:@logdev).singleton_class.prepend(hook)
logger.info("rotate")
puts "logger #{Logger::VERSION}: #{result}"
reader.close
logger.close
end
Output on Windows 10 (ruby 3.4.13 x64-mingw-ucrt):
logger 1.6.2: read 1143 bytes
logger 1.6.3: Errno::EACCES: Permission denied @ io_fread - .../app.log
logger 1.7.0: Errno::EACCES: Permission denied @ io_fread - .../app.log
Possible fix
One option on Windows is to use LockFileEx to lock a single byte far beyond EOF. Windows allows this, and reads of the log data do not overlap that byte. Rotators that lock the same byte would still wait for each other. A whole-file flock from logger 1.6.3 to 1.7.0 also covers that byte, so mixed versions would still exclude each other. Raymond Chen describes this technique in You can use a file as a synchronization object, too.
The draft PR fluent/fluentd#5690 tries this approach. It overrides lock_shift_log and calls LockFileEx through Fiddle. If you prefer not to call a Win32 API from logger, could the locking step be made overridable?
Related behavior
create_logfile also holds flock(File::LOCK_EX) while writing a new log header. It holds the lock for much less time. Older versions also lock the file here.
#165 is another Windows problem around lock_shift_log after logger 1.6.2.
- Linguagem predominante
- Ruby
- Estrelas
- 161
- Forks
- 76
- Merge médio
- 2d 5h
- PRs com merge (30d)
- 3
Preparar o ambiente
Este projeto não oferece contêiner de desenvolvimento, Dockerfile nem guia de contribuição, então a configuração fica por sua conta: comece pelo README e veja nosso guia da primeira contribuição para os passos gerais.
Primeiros passos
- Leia a issue inteira e depois o guia de contribuição do projeto.
- Comente na issue dizendo que vai assumir — evita que duas pessoas façam o mesmo trabalho.
- Faça um fork do repositório e trabalhe em uma branch.
- Abra um pull request que referencie o número da issue.
Mais de ruby/logger
-
Programs using Logger sometimes resist SIGTERM / SIGINTTalvez já em andamento Um pull request vinculado a esta issue está aberto ou já foi mesclado. Aberta
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 82/100
-
Later writes fail with "closed stream" when renaming the log fails during rotation on WindowsAberta
Dificuldade 3/5 1-2 dias Facilidade para iniciantes 68/100
-
Dificuldade 3/5 1-2 dias Facilidade para iniciantes 52/100
-
`datetime_format=` does not apply to custom formattersTalvez já em andamento @Rubyist007 assumiu há 229 dias. Aberta
Dificuldade 3/5 1-2 dias Facilidade para iniciantes 72/100
-
Dificuldade 4/5 3-5 dias Facilidade para iniciantes 35/100
Todas as issues de ruby/logger
Issues semelhantes
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 72/100
Mantenedores costumam responder em até 1 dia
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 85/100
open-feature/ruby-sdk-contrib#340 ·
Mantenedores costumam responder em até 1 dia
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 88/100
zold-io/wts.zold.io#651 ·
Mantenedores costumam responder em até 1 dia
-
good first issue help wanted
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 87/100
erkamyaman/rust-anything#788 ·
Mantenedores costumam responder em até 1 dia
-
Dificuldade 1/5 Menos de uma hora Facilidade para iniciantes 74/100
TheOdinProject/curriculum#31579 ·
Mantenedores costumam responder em até 1 dia