ISIS alarm improvement work

未关闭
#3,995 0 条评论 0 个 reaction 已指派 0 人 在 GitHub 查看

维护者通常 1 天内回复

还没有人认领这个 Issue。

评估

难度
5/5
预计耗时
一周以上
新手友好度
25/100
Issue 类型
功能
描述清晰度
需要澄清
活跃度
活跃
技术栈
java
领域
tooling

调研方向

The issue lists alarm tree and configuration work, including related pull requests #3991 and #3988, but does not identify source files or tests. Start by reading those pull requests and locating the alarm tree and configuration entry points in the Java project. The list covers multiple independent changes and open design questions; done would need to be defined for a specific item before implementation.

由索引模型根据 Issue 内容生成。

描述

Following up on the discussions during the monthly meetings and the Codeathon, I have created a more precise list of work I want to do on the alarm system over the next few months.

Thought it best to create a issue so that the alarm work I'm planning is written down somewhere (please let me know if you'd prefer this split up into multiple issues).

I'm not 100% sure on how every work item should be implemented and whether any will cause problems for other facilities, so please let me know any thoughts or if anyone is interested in helping, discussion is very welcome and this issue will likely evolve.

Context

I am an industrial placement student (i.e. senior intern™) working at ISIS Neutron and Muon source until August, focused on alarms.

We are migrating from an old control system (Vista) to EPICS. As part of this work, we are migrating and improving our alarm system. Over the last 2 months I have talked with our control room crew and head of operations to find out the current issues with the alarm system, prototyped some solutions, and gathered feedback and iterated on them. I have discussed most of these work items at the monthly meetings and was present for the alarm discussion at the Codeathon.

Alarm configuration improvements

  • (https://github.com/ControlSystemStudio/phoebus/pull/3991) Add 'editing mode' to alarm tree as discussed in Codeathon
  • Remove configuration dialog box and embed alarm configuration options into a panel on the right side of the alarm tree
    • Panel hidden when not in editing mode
    • Have to click 'save changes' or similar for changes to be sent to Kafka
  • Alarm configuration table improvements
    • Improve UI for tables by allowing drag/drop, copy/paste, adding keybinds, potentially adding a context menu - not 100% sure what this will involve yet
  • Clientside checking for enabling filter
    • Syntax checking to make sure the expression 'compiles'
    • Live checking of whether the expression evaluates to true or false
    • Have not looked into this at all yet - may be technically impractical
  • Drag and drop
    • Allow selected alarms/components to be dragged and dropped
  • Copy/cut/paste
    • Allow selected alarms/components to be copied/cut/pasted with buttons in the context menu
    • Remove 'move item' after both this and drag/drop are implemented
  • Remove 'rename item' and allow the item to be renames in the configuration menu

Prototype:

https://github.com/user-attachments/assets/0b483e32-c550-4fb4-ae2c-e6c2c65720b4

General alarm tree improvements

  • (https://github.com/ControlSystemStudio/phoebus/pull/3988) Add PV search bar to alarm tree
  • Replace alarm tree expand buttons with filter
    • Remove the 'expand to show [active|disabled] alarms' buttons and replace them with a dropdown containing tri-state checkboxes: 'Active alarms', 'Disabled alarms', 'Acknowledged alarms' (is this too convoluted?)
    • This may break workflows, but a filter seems like it would be a more intuitive and useful way to interact with the alarm tree, and having both options seems like a confusing middle ground (any thoughts?)
    • It would be useful to be able to automatically expand nodes to see the leafs when a filter is active, but this would not work well if you set it to e.g. all inactive alarms. Not sure how to handle this yet
  • Alarm tree context menu improvements
    • Collapse guidances into 'N guidances...' if the number of guidances exceeds a threshold, rather than truncating them
    • Collapse screens into 'N screens...' if the number of screens exceeds a threshold, rather than truncating them
    • Change 'Remove selected items' to 'Remove [N] items', and the same for enable/disable (counts components and their children)

Alarm disable improvements

  • Alarm disabling UI improvements
    • Merge 'disable indefinitely' and 'disable until' options into one single dialog box
    • Box lists all PVs/components to be disabled and the number of alarms to be disabled at the top
    • Box would have a radio selection with options 'Indefinitely', 'Custom', and a set of predefined times from settings
    • Predefined times can be relative (5 minutes, 1 century) or absolute (15:00, Monday 16:50) (why absolute? may want to disable alarm until next shift, end of cycle, or similar - addresses common periodic events)
  • Alarm disable reasons
    • Add a 'Disable reason' radio selection to the alarm disable dialog box containing a set of predefined reasons from settings, or 'custom'
    • To make this a non-breaking change, reasons can be null - but add an option to settings.ini to require operators to add a reason
    • Change alarm tree to display disabled reason alongside 'Disabled'
    • Change config dialog box to display disabled reason next to 'Enabled' (enabled checkbox will need to be moved)

Prototype:

Image
主要语言
Java
星标
130
派生
132
平均合并
2 天 11 小时
30 天内合并 PR
23

环境准备

  • 没有 Dockerfile 或 Docker Compose 文件
  • 有 Pull Request 模板
  • 没有贡献指南

从这里开始

  1. 先读完整个 Issue,再读项目的贡献指南。
  2. 在 Issue 下留言说明你要接手 —— 这能避免两个人做同样的事。
  3. Fork 仓库,在一个分支上完成修改。
  4. 提交 Pull Request,并在描述里引用这个 Issue 编号。

ControlSystemStudio/phoebus 的其他 Issue

查看 ControlSystemStudio/phoebus 的全部 Issue

相似的 Issue

更多 Java Issue

把新 issue 发到你的邮箱

精选适合新手参与的 GitHub issue 摘要。