WaveformView (geometry mode): Alt + wheel scales x around probe x = 0, so snippets shift instead of widening on channels far from x = 0

Đang mở
#286 0 bình luận 0 reaction 0 người được giao Xem trên GitHub

Chưa có ai nhận issue này.

Đánh giá

Độ khó
3/5
Thời gian dự kiến
1-2 ngày
Mức phù hợp với người mới
68/100
Loại issue
Lỗi
Độ rõ ràng
Đặc tả rõ ràng
Mức độ hoạt động
Sôi nổi
Công nghệ
python
Lĩnh vực
desktop, frontend

Hướng nghiên cứu

Start in waveformview.py at the initialization around line 78 and the geometry drawing sites around lines 468, 587, 632, 1087, 1239, and 1314; compare the Qt and Panel paths, including the Panel factor update around line 1049. Check existing waveform-view tests and reproduce with a unit on a contact far from x = 0. Done when Alt + wheel widens snippets around their contact positions across shanks without shifting them out of view.

Do mô hình lập chỉ mục viết ra từ nội dung của issue.

Mô tả

Description

In the WaveformView in geometry mode, Alt + mouse wheel (widen/narrow x axis) multiplies the absolute x coordinates of the snippets by factor_x. Each snippet is built around its contact position:

waveformview.py, line 78

self.xvect[chan_ind, :] = np.linspace(x - espx, x + espx, num=width)
and is then drawn as:

waveformview.py, line 468 (also lines 587, 632, 1087, 1239, 1314)

xvectors = self.xvect[common_channel_indexes, :] * self.factor_x
So the scaling happens around x = 0 of the probe, not around each contact. For units on contacts near x = 0 the snippet widens as expected. For units on contacts far from x = 0, each wheel step mostly translates the snippet sideways (by about 30% of its x position, since factor_x changes by a factor of 1.3). Because the refresh keeps the view range (keep_range=True), the waveform appears to move rather than widen and soon leaves the view.

This is very visible on multi-shank probes. With a Neuropixels 2.0 4-shank probe (shanks about 250 µm apart), widening works on shank 0 and is unusable on shanks 1–3.

To reproduce:

Open a SortingAnalyzer from a multi-shank probe (or any probe with contacts at large x).
In WaveformView (geometry mode), select a unit on a contact far from x = 0.
Alt + mouse wheel: the snippet slides horizontally instead of widening in place.
Expected: the snippet widens around its own contact position.

Possible fix: scale around each contact's x position, e.g. keep the contact x per channel and use

xvectors = xcenter[:, None] + (self.xvect[common_channel_indexes, :] - xcenter[:, None]) * self.factor_x
where xcenter holds the contact x positions of common_channel_indexes. The same applies to the other places where self.xvect * self.factor_x is used, including the Panel backend (factor_x updated at line 1049).

Environment: spikeinterface-gui 0.13.1 (same code on current main), spikeinterface 0.104.8, desktop (Qt / PySide6), Windows 10, Python 3.10.

Ngôn ngữ chính
Python
Star
72
Fork
23
Merge trung bình
4 ngày 4 giờ
Pull request đã merge (30 ngày)
5

Chuẩn bị môi trường

Dự án này không cung cấp dev container, Dockerfile hay hướng dẫn đóng góp, nên bạn cần tự thiết lập môi trường: hãy bắt đầu từ README và xem hướng dẫn đóng góp lần đầu của chúng tôi để biết các bước chung.

Bắt đầu từ đâu

  1. Đọc hết issue, rồi đọc hướng dẫn đóng góp của dự án.
  2. Bình luận trên issue rằng bạn sẽ nhận — tránh hai người làm cùng một việc.
  3. Fork repository và làm thay đổi trên một nhánh.
  4. Mở pull request có tham chiếu số hiệu của issue.

Issue khác của SpikeInterface/spikeinterface-gui

Tất cả issue của SpikeInterface/spikeinterface-gui

Issue tương tự

Thêm issue về Python

Nhận issue mới trong hộp thư của bạn

Bản tóm tắt ngắn những issue GitHub phù hợp với người mới.