Hacktoberfest 2026:メンテナが10月に向けて印を付けた、オープンで初心者向けの issue。 Hacktoberfest の issue を見る

feat(wasserfoerderung): FI 5.008 planner engine with per-pump pressures

オープン
#584 コメント 0 件 リアクション 0 件 担当者 0 名 GitHub で見る

メンテナーはふだん 1 日以内に返信

まだ誰も着手していません。

評価

難易度
4/5
見積もり時間
3〜5日
初心者へのやさしさ
22/100
issue の種類
機能追加
明瞭さ
おおむね明確
活発さ
活発
技術スタック
csharp
領域
backend

調査の方向性

Start from FörderstreckePlanner on the branch feat/wasserfoerderung-plan-a and the friction table it uses, then compare it with FI 5.008 Tab. 3. The golden tests should reproduce Abb. 22 (0/540/920/1260 m) and Abb. 23 (0/458/579 m). Done means those tests pass, plus new tests for downhill overpressure, an infeasible steep segment, a route shorter than one hose, and a partial last segment. The review comment on #150 holds context not in the payload and should be read first.

索引モデルが issue の本文から書いたものです。

説明

Slice 1 of the Wasserförderung restart (#150). Domain only — no UI, no persistence, no sync. Analysis and rationale: see the review comment on #150.

Why

The planner on feat/wasserfoerderung-plan-a (FörderstreckePlanner) has problems in its hydraulics:

  • Its friction table is optimistic compared with FI 5.008 Tab. 3: 1,0 vs. 1,2 bar/100 m at 800 l/min. At 8 bar / 1,5 bar it plans a 620 m flat leg where FI 5.008 Abb. 22 gives 540 m, so pumps end up ~15 % too far apart.
  • On a descent Cost() goes negative and the leg keeps extending. Nothing checks overpressure against the B hose's 16 bar.
  • It returns only counts and positions in metres. There are no per-pump pressures.
  • The reserve is a unitless "3 % of budget" instead of a pressure in bar.
Scope
  • Friction per FI 5.008 Tab. 3 (600/800/1000/1200 l/min), cited in the code.
  • Inputs: Förderstrom, pump type / Ausgangsdruck (8 or 10 bar), min. Eingangsdruck, Sicherheitsreserve in bar, Warnschwelle, optional Einsatzstellenpumpe at the target.
  • Input profile as Stützpunkte (Strecke m, Höhe m), interpolated to 20 m stations. Keep the branch's worst-interior-point crest check.
  • Result per pump: role (Wasserentnahmestelle / Verstärkerpumpe / Einsatzstellenpumpe), station, Höhe, Eingangsdruck, Ausgangsdruck, section length / rise / B-20 count.
  • Typed findings instead of exceptions where the plan is still usable: overpressure downhill, a segment that cannot be pumped at all, Restdruck at the target below the minimum, >1000 l/min → Doppelleitung.
  • A partial last segment is charged pro rata, not as a full 20 m. Hose totals equal the sum of the sections.
Out of scope / open
  • Offene Schaltreihe: model it correctly (every pump draws from a Faltbehälter) or leave it out. Re-checking only the last stretch is not enough.
  • The DBV setting, reserve pump ratio and reserve hose rule need a cited source before they are shown as instructions.
Acceptance
  • Golden tests reproduce FI 5.008 Abb. 22 (0/540/920/1260 m, 0/0/19,2/43,2 m, 8 bar, 800 l/min) and Abb. 23 (0/458/579 m, 0/14/19 m).
  • Tests cover a downhill overpressure case, an infeasible steep segment, a route shorter than one hose, and a partial last segment.

🤖 Generated with Claude Code

主要言語
C#
スター
1
フォーク
3
平均マージ
4時間 34分
マージ済み PR(30日)
182

環境構築

はじめの一歩

  1. issue を最後まで読み、次にプロジェクトのコントリビューションガイドを読みます。
  2. 着手することを issue にコメントします — 二人が同じ作業をするのを防げます。
  3. リポジトリをフォークし、ブランチを切って変更します。
  4. issue 番号を参照したプルリクエストを送ります。

CodeForFire/lagebuch のほかの issue

CodeForFire/lagebuch の issue をすべて見る

似ている issue

C# の issue をもっと見る

新しい issue をメールで受け取る

初心者向けの GitHub issue を短くまとめたダイジェスト。