Hacktoberfest 2026: los issues que los mantenedores marcaron para octubre, abiertos y aptos para principiantes. Explorar issues de Hacktoberfest

feat(wasserfoerderung): FI 5.008 planner engine with per-pump pressures

Abierto
#584 0 comentarios 0 reacciones 0 asignados Ver en GitHub

Los mantenedores suelen responder en 1 día

Nadie ha tomado este issue todavía.

Evaluación

Dificultad
4/5
Tiempo estimado
3-5 días
Aptitud para principiantes
22/100
Tipo de issue
Nueva funcionalidad
Claridad
Bastante claro
Estado de actividad
Activo
Stack tecnológico
csharp
Área
backend

Línea de trabajo

Start from FörderstreckePlanner on the branch feat/wasserfoerderung-plan-a and the friction table it uses, then compare it with FI 5.008 Tab. 3. The golden tests should reproduce Abb. 22 (0/540/920/1260 m) and Abb. 23 (0/458/579 m). Done means those tests pass, plus new tests for downhill overpressure, an infeasible steep segment, a route shorter than one hose, and a partial last segment. The review comment on #150 holds context not in the payload and should be read first.

Escrito por el modelo de indexación a partir del texto del issue.

Descripción

Slice 1 of the Wasserförderung restart (#150). Domain only — no UI, no persistence, no sync. Analysis and rationale: see the review comment on #150.

Why

The planner on feat/wasserfoerderung-plan-a (FörderstreckePlanner) has problems in its hydraulics:

  • Its friction table is optimistic compared with FI 5.008 Tab. 3: 1,0 vs. 1,2 bar/100 m at 800 l/min. At 8 bar / 1,5 bar it plans a 620 m flat leg where FI 5.008 Abb. 22 gives 540 m, so pumps end up ~15 % too far apart.
  • On a descent Cost() goes negative and the leg keeps extending. Nothing checks overpressure against the B hose's 16 bar.
  • It returns only counts and positions in metres. There are no per-pump pressures.
  • The reserve is a unitless "3 % of budget" instead of a pressure in bar.
Scope
  • Friction per FI 5.008 Tab. 3 (600/800/1000/1200 l/min), cited in the code.
  • Inputs: Förderstrom, pump type / Ausgangsdruck (8 or 10 bar), min. Eingangsdruck, Sicherheitsreserve in bar, Warnschwelle, optional Einsatzstellenpumpe at the target.
  • Input profile as Stützpunkte (Strecke m, Höhe m), interpolated to 20 m stations. Keep the branch's worst-interior-point crest check.
  • Result per pump: role (Wasserentnahmestelle / Verstärkerpumpe / Einsatzstellenpumpe), station, Höhe, Eingangsdruck, Ausgangsdruck, section length / rise / B-20 count.
  • Typed findings instead of exceptions where the plan is still usable: overpressure downhill, a segment that cannot be pumped at all, Restdruck at the target below the minimum, >1000 l/min → Doppelleitung.
  • A partial last segment is charged pro rata, not as a full 20 m. Hose totals equal the sum of the sections.
Out of scope / open
  • Offene Schaltreihe: model it correctly (every pump draws from a Faltbehälter) or leave it out. Re-checking only the last stretch is not enough.
  • The DBV setting, reserve pump ratio and reserve hose rule need a cited source before they are shown as instructions.
Acceptance
  • Golden tests reproduce FI 5.008 Abb. 22 (0/540/920/1260 m, 0/0/19,2/43,2 m, 8 bar, 800 l/min) and Abb. 23 (0/458/579 m, 0/14/19 m).
  • Tests cover a downhill overpressure case, an infeasible steep segment, a route shorter than one hose, and a partial last segment.

🤖 Generated with Claude Code

Lenguaje dominante
C#
Estrellas
1
Forks
3
Merge medio
4 h 49 min
PR fusionados (30 d)
177

Preparar el entorno

Primeros pasos

  1. Lee el issue completo y luego la guía de contribución del proyecto.
  2. Comenta en el issue que vas a ocuparte — evita que dos personas hagan lo mismo.
  3. Haz un fork del repositorio y trabaja en una rama.
  4. Abre un pull request que haga referencia al número del issue.

Más de CodeForFire/lagebuch

Todos los issues de CodeForFire/lagebuch

Issues similares

Más issues de C#

Recibe los nuevos issues en tu correo

Un resumen breve de issues de GitHub para principiantes.