Hacktoberfest 2026: le issue che i maintainer hanno segnato per ottobre, aperte e adatte ai principianti. Sfoglia le issue Hacktoberfest

[Bug]: LilyGo T-Beam V1.2 (SX1276/AXP2101) - BME280 sensor data corrupted (wrong temp ~52-65°C, humidity/pressure missing)

Aperta
#3,580 0 commenti 0 reazioni 0 assegnatari Vedi su GitHub

I maintainer di solito rispondono entro 1 giorno

Nessuno ha ancora preso questa issue.

Valutazione

Difficoltà
4/5
Tempo stimato
3-5 giorni
Idoneità per principianti
48/100
Tipo di issue
Bug
Chiarezza
Abbastanza chiara
Stato di attività
Attiva
Stack tecnologico
c
Ambito
embedded-iot

Direzione di ricerca

Start by locating the BME280 driver and the LilyGo T-Beam V1.2 (SX1276) board initialization path, then trace the I2C startup and calibration register reads. Compare the reported temperature with the missing humidity and pressure values to identify where initialization or compensation data fails. Done means the sensor initializes reliably and reports plausible temperature, humidity, and pressure on this board.

Scritto dal modello di indicizzazione a partire dal testo della issue.

Descrizione

[Bug]: LilyGo T-Beam V1.2 (SX1276/AXP2101) - BME280 sensor data corrupted (wrong temp ~52-65°C, humidity/pressure missing)
Description:
Hi developers,
I am facing an issue with an external BME280 sensor connected to a LilyGo T-Beam V1.2 (SX1276 with AXP2101 PMU) running the latest MeshCore firmware.
The exact same hardware setup was previously running flawlessly under Meshtastic, so a hardware or wiring defect can be 100% ruled out.
Hardware Setup:
• Board: LilyGo T-Beam V1.2 (SX1276 / AXP2101)
• Sensor: BME280 (3.3V version, 6-pin breakout board)
• Wiring:
• SDA connected to GPIO 21
• SCL connected to GPIO 22
• SDO hardwired to GND (forcing I2C address 0x76)
• CSB hardwired to 3V3 (forcing I2C mode)
• Peripherals: An OLED display is sharing the same I2C bus (Pins 21/22 and 3V3/GND) and works perfectly fine.
The Problem:
When using MeshCore (flashed via the official web flasher using the LilyGo T-Beam 1.2 (SX1276) target), the BME280 sensor fails to initialize properly:

  1. Temperature: The MeshCore App displays an absurdly high, incorrect temperature reading between 52°C and 65°C at normal room temperature.
  2. Humidity & Pressure: Both values are completely missing/not populated in the telemetry layout.
    Suspected Cause:
    It seems like a timing issue with the AXP2101 PMU during the boot sequence or a calculation error within the sensor driver's compensation registers. Because the OLED display initializes on the same rail, a minor voltage dip at startup might cause the BME280 to fail reading its internal calibration EPROM data, leading to corrupt raw data interpretation (which mathematically ends up as ~52-65°C).
    Could you please look into the I2C startup sequence or the BME280 calibration register readout for the T-Beam V1.2 target?
    Thank you for your amazing work on MeshCore!
Lingua principale
C
Stelle
3.9k
Fork
1.5k
Merge medio
18h 59m
PR unite (30g)
28

Preparare l'ambiente

Questo progetto non fornisce container di sviluppo, Dockerfile né guida per i contributori, quindi l'ambiente è a tuo carico: parti dal suo README e consulta la nostra guida al primo contributo per i passaggi generali.

Come iniziare

  1. Leggi tutta la issue e poi la guida ai contributi del progetto.
  2. Commenta sulla issue per dire che te ne occupi tu — evita che due persone facciano lo stesso lavoro.
  3. Fai un fork del repository e lavora su un branch.
  4. Apri una pull request che faccia riferimento al numero della issue.

Altre issue di meshcore-dev/MeshCore

Tutte le issue di meshcore-dev/MeshCore

Issue simili

Altre issue su C

Ricevi le nuove issue nella tua casella

Un breve riepilogo di issue GitHub adatte ai principianti.