[Bug]: LilyGo T-Beam V1.2 (SX1276/AXP2101) - BME280 sensor data corrupted (wrong temp ~52-65°C, humidity/pressure missing)

Abierto
#3,580 0 comentarios 0 reacciones 0 asignados Ver en GitHub

Los mantenedores suelen responder en 1 día

Nadie ha tomado este issue todavía.

Evaluación

Dificultad
4/5
Tiempo estimado
3-5 días
Aptitud para principiantes
48/100
Tipo de issue
Error
Claridad
Bastante claro
Estado de actividad
Activo
Stack tecnológico
c
Área
embedded-iot

Línea de trabajo

Start by locating the BME280 driver and the LilyGo T-Beam V1.2 (SX1276) board initialization path, then trace the I2C startup and calibration register reads. Compare the reported temperature with the missing humidity and pressure values to identify where initialization or compensation data fails. Done means the sensor initializes reliably and reports plausible temperature, humidity, and pressure on this board.

Escrito por el modelo de indexación a partir del texto del issue.

Descripción

[Bug]: LilyGo T-Beam V1.2 (SX1276/AXP2101) - BME280 sensor data corrupted (wrong temp ~52-65°C, humidity/pressure missing)
Description:
Hi developers,
I am facing an issue with an external BME280 sensor connected to a LilyGo T-Beam V1.2 (SX1276 with AXP2101 PMU) running the latest MeshCore firmware.
The exact same hardware setup was previously running flawlessly under Meshtastic, so a hardware or wiring defect can be 100% ruled out.
Hardware Setup:
• Board: LilyGo T-Beam V1.2 (SX1276 / AXP2101)
• Sensor: BME280 (3.3V version, 6-pin breakout board)
• Wiring:
• SDA connected to GPIO 21
• SCL connected to GPIO 22
• SDO hardwired to GND (forcing I2C address 0x76)
• CSB hardwired to 3V3 (forcing I2C mode)
• Peripherals: An OLED display is sharing the same I2C bus (Pins 21/22 and 3V3/GND) and works perfectly fine.
The Problem:
When using MeshCore (flashed via the official web flasher using the LilyGo T-Beam 1.2 (SX1276) target), the BME280 sensor fails to initialize properly:

  1. Temperature: The MeshCore App displays an absurdly high, incorrect temperature reading between 52°C and 65°C at normal room temperature.
  2. Humidity & Pressure: Both values are completely missing/not populated in the telemetry layout.
    Suspected Cause:
    It seems like a timing issue with the AXP2101 PMU during the boot sequence or a calculation error within the sensor driver's compensation registers. Because the OLED display initializes on the same rail, a minor voltage dip at startup might cause the BME280 to fail reading its internal calibration EPROM data, leading to corrupt raw data interpretation (which mathematically ends up as ~52-65°C).
    Could you please look into the I2C startup sequence or the BME280 calibration register readout for the T-Beam V1.2 target?
    Thank you for your amazing work on MeshCore!
Lenguaje dominante
C
Estrellas
3.9k
Forks
1.5k
Merge medio
18 h 59 min
PR fusionados (30 d)
28

Preparar el entorno

Este proyecto no incluye contenedor de desarrollo, Dockerfile ni guía de contribución, así que la configuración corre por tu cuenta: empieza por su README y consulta nuestra guía para la primera contribución para los pasos generales.

Primeros pasos

  1. Lee el issue completo y luego la guía de contribución del proyecto.
  2. Comenta en el issue que vas a ocuparte — evita que dos personas hagan lo mismo.
  3. Haz un fork del repositorio y trabaja en una rama.
  4. Abre un pull request que haga referencia al número del issue.

Más de meshcore-dev/MeshCore

Todos los issues de meshcore-dev/MeshCore

Issues similares

Más issues de C

Recibe los nuevos issues en tu correo

Un resumen breve de issues de GitHub para principiantes.