Follow-ups left open by the station identity seam (#460)
I maintainer di solito rispondono entro 1 giorno
Nessuno ha ancora preso questa issue.
Valutazione
- Difficoltà
- 5/5
- Tempo stimato
- Più di una settimana
- Idoneità per principianti
- 25/100
- Tipo di issue
- Funzionalità
- Chiarezza
- Abbastanza chiara
- Stato di attività
- Attiva
- Stack tecnologico
- c, linux
- Ambito
- embedded-iot, networking, testing
Direzione di ricerca
Start with the named entry points IRadio::SetStationIdentity, Mt7612uRadio::StartRxLoop, src/sta, and the scripts tests/mt7612u_sta_uplink.sh and tests/mt7612u_sta_identity.sh; the issue also points to gate_txs from #452. First identify one bounded follow-up, then review the existing measurements and harness requirements. Done criteria depend on the chosen item; for station behavior, the issue specifies both addressed-station receive/acknowledgment and the station's own unicast acknowledgment.
Scritto dal modello di indicizzazione a partire dal testo della issue.
Descrizione
Follow-ups left open by #460 (IRadio::SetStationIdentity, the MT7612U station arm, merged as 77b907a). None blocks the seam; each is a measurement or a port that the PR named and did not do.
Library
- The Realtek station arm.
SetStationIdentityreturns the not-portedfalseon Jaguar1/2/3, Kestrel and the RTL8733B. On Realtek the MACID / BSSID registers and the ACK responder relate differently from the MT7612U's port identity, so the seam needs its own measured arm per family, with the same two halves of the bar (station_mode_ok): unicast addressed to the station received and acknowledged, and the station's own unicast acknowledged. - A role-selected managed receive filter on the MT7612U.
Mt7612uRadio::StartRxLoopinstalls the monitor filter unconditionally, so a station driven throughIRadioruns promiscuous and never runs the managed filter0x00015f97the cells measured. "Moving the port identity makes a station deaf" is a managed-filter property; under the monitor filter it keeps receiving and stops acknowledging. - The
src/stacaller. Nothing in-tree callsSetStationIdentityyet. The station harness that associates throughIRadioover thesrc/stacore (frames, supplicant, CCMP,DupDetector) is what exercises the arm-then-measure path the cells did not run, and is where thetx.retry_limit == 0warning gets bench-checked.
Measurements
- The BSSID receive table on a second rig. The second unit (CF-922AC,
40:a5:ef:5f:65:51) reproducedstaid, autoack, uplink andstaackarm C, but thestatable stalled twice on an rtw88 AP (RTL8812BU on a SuperSpeed root port,failed to get tx report from firmware; injector at 100/s and 8/s of 300). The harness refused both, correctly. A non-rtw88 AP (vendorrtl88x2bubuilt for the rig kernel, or a non-Realtek AP) is needed to reproduce the table off the author's rig. - The 6 fps
txsgate loses one status entry per arm on the second unit. Every ~6 fps arm reads 199/200 (or 59/60) while the high-fps arms settle 200/200; the author's unit settles all of them.tests/mt7612u_sta_uplink.shrefuses any deficit on a claiming arm, so on that unit the uplink half ofstation_mode_ok's bar is INCONCLUSIVE 3 runs out of 4 with arm A at 199/200 acknowledged, 0.0 mean retries, against 0/158 at 16.0. Either find the lost entry in the status-FIFO drain (gate_txs, from #452) or give the claiming arm a bounded tolerance. - Uplink mean retries differ between units: 0.0 on the author's, 1.9 on the second (cc48be4 run, 60/60). Stated in the doc, unexplained.
- The unexplained first-arm excess. Arm A of the BSSID table sits 4–7% above B–F in every run; with one run per arm it cannot be separated from drift, and a real few-percent BSSID-register effect would hide inside it.
- Unassociated cells only. Power save, TIM parsing, cross-BSS duplicate detection and hardware key lookup are untested on the MT7612U.
Harness
tests/mt7612u_sta_identity.sh's rig requirement ("both adapters at high speed, no full-speed hub") is necessary, not sufficient: the rtw88 stall also happened on a SuperSpeed root port.
- Lingua principale
- C
- Stelle
- 56
- Fork
- 29
- Merge medio
- 3h 43m
- PR unite (30g)
- 75
Preparare l'ambiente
Questo progetto non fornisce container di sviluppo, Dockerfile né guida per i contributori, quindi l'ambiente è a tuo carico: parti dal suo README e consulta la nostra guida al primo contributo per i passaggi generali.
Come iniziare
- Leggi tutta la issue e poi la guida ai contributi del progetto.
- Commenta sulla issue per dire che te ne occupi tu — evita che due persone facciano lo stesso lavoro.
- Fai un fork del repository e lavora su un branch.
- Apri una pull request che faccia riferimento al numero della issue.
Altre issue di OpenIPC/devourer
-
Difficoltà 2/5 1-3 ore Idoneità per principianti 82/100
I maintainer di solito rispondono entro 1 giorno
-
Follow-ups left open by the 8822B fast bandwidth toggle fix (#584)Forse già presa @josephnef l’ha presa oggi. Apertaenhancement
Difficoltà 4/5 3-5 giorni Idoneità per principianti 42/100
I maintainer di solito rispondono entro 1 giorno
-
Difficoltà 5/5 Più di una settimana Idoneità per principianti 12/100
OpenIPC/devourer#579 · 1 commento ·
I maintainer di solito rispondono entro 1 giorno
-
enhancement
Difficoltà 5/5 Più di una settimana Idoneità per principianti 12/100
I maintainer di solito rispondono entro 1 giorno
-
enhancement
Difficoltà 5/5 Più di una settimana Idoneità per principianti 8/100
I maintainer di solito rispondono entro 1 giorno
Tutte le issue di OpenIPC/devourer
Issue simili
-
Difficoltà 2/5 1-3 ore Idoneità per principianti 72/100
I maintainer di solito rispondono entro 1 giorno
-
Needs-Triage
Difficoltà 2/5 1-3 ore Idoneità per principianti 66/100
I maintainer di solito rispondono entro 2 giorni
-
issue: bug report
Difficoltà 2/5 1-3 ore Idoneità per principianti 82/100
I maintainer di solito rispondono entro 2 giorni
-
cross-platform fix-now
Difficoltà 2/5 1-3 ore Idoneità per principianti 76/100
I maintainer di solito rispondono entro 1 giorno
-
feature:index kind:crash status:confirmed triaged
Difficoltà 2/5 1-3 ore Idoneità per principianti 77/100
clice-io/clice#1123 · 1 commento ·
I maintainer di solito rispondono entro 1 giorno