Follow-ups left open by the station identity seam (#460)
Les mainteneurs répondent en général sous 1 jour
Personne n'a encore pris cette issue.
Évaluation
- Difficulté
- 5/5
- Temps estimé
- Plus d'une semaine
- Accessibilité débutants
- 25/100
- Type d'issue
- Fonctionnalité
- Clarté
- Plutôt claire
- Activité
- Active
- Stack technique
- c, linux
- Domaine
- embedded-iot, networking, testing
Piste de recherche
Start with the named entry points IRadio::SetStationIdentity, Mt7612uRadio::StartRxLoop, src/sta, and the scripts tests/mt7612u_sta_uplink.sh and tests/mt7612u_sta_identity.sh; the issue also points to gate_txs from #452. First identify one bounded follow-up, then review the existing measurements and harness requirements. Done criteria depend on the chosen item; for station behavior, the issue specifies both addressed-station receive/acknowledgment and the station's own unicast acknowledgment.
Rédigé par le modèle d'indexation à partir du texte de l'issue.
Description
Follow-ups left open by #460 (IRadio::SetStationIdentity, the MT7612U station arm, merged as 77b907a). None blocks the seam; each is a measurement or a port that the PR named and did not do.
Library
- The Realtek station arm.
SetStationIdentityreturns the not-portedfalseon Jaguar1/2/3, Kestrel and the RTL8733B. On Realtek the MACID / BSSID registers and the ACK responder relate differently from the MT7612U's port identity, so the seam needs its own measured arm per family, with the same two halves of the bar (station_mode_ok): unicast addressed to the station received and acknowledged, and the station's own unicast acknowledged. - A role-selected managed receive filter on the MT7612U.
Mt7612uRadio::StartRxLoopinstalls the monitor filter unconditionally, so a station driven throughIRadioruns promiscuous and never runs the managed filter0x00015f97the cells measured. "Moving the port identity makes a station deaf" is a managed-filter property; under the monitor filter it keeps receiving and stops acknowledging. - The
src/stacaller. Nothing in-tree callsSetStationIdentityyet. The station harness that associates throughIRadioover thesrc/stacore (frames, supplicant, CCMP,DupDetector) is what exercises the arm-then-measure path the cells did not run, and is where thetx.retry_limit == 0warning gets bench-checked.
Measurements
- The BSSID receive table on a second rig. The second unit (CF-922AC,
40:a5:ef:5f:65:51) reproducedstaid, autoack, uplink andstaackarm C, but thestatable stalled twice on an rtw88 AP (RTL8812BU on a SuperSpeed root port,failed to get tx report from firmware; injector at 100/s and 8/s of 300). The harness refused both, correctly. A non-rtw88 AP (vendorrtl88x2bubuilt for the rig kernel, or a non-Realtek AP) is needed to reproduce the table off the author's rig. - The 6 fps
txsgate loses one status entry per arm on the second unit. Every ~6 fps arm reads 199/200 (or 59/60) while the high-fps arms settle 200/200; the author's unit settles all of them.tests/mt7612u_sta_uplink.shrefuses any deficit on a claiming arm, so on that unit the uplink half ofstation_mode_ok's bar is INCONCLUSIVE 3 runs out of 4 with arm A at 199/200 acknowledged, 0.0 mean retries, against 0/158 at 16.0. Either find the lost entry in the status-FIFO drain (gate_txs, from #452) or give the claiming arm a bounded tolerance. - Uplink mean retries differ between units: 0.0 on the author's, 1.9 on the second (cc48be4 run, 60/60). Stated in the doc, unexplained.
- The unexplained first-arm excess. Arm A of the BSSID table sits 4–7% above B–F in every run; with one run per arm it cannot be separated from drift, and a real few-percent BSSID-register effect would hide inside it.
- Unassociated cells only. Power save, TIM parsing, cross-BSS duplicate detection and hardware key lookup are untested on the MT7612U.
Harness
tests/mt7612u_sta_identity.sh's rig requirement ("both adapters at high speed, no full-speed hub") is necessary, not sufficient: the rtw88 stall also happened on a SuperSpeed root port.
- Langage dominant
- C
- Étoiles
- 56
- Forks
- 29
- Merge moyen
- 3 h 43 min
- PR mergées (30 j)
- 75
Préparer son environnement
Ce projet ne fournit ni conteneur de développement, ni Dockerfile, ni guide de contribution : l'installation est à votre charge. Commencez par son README, et consultez notre guide de la première contribution pour les étapes générales.
Par où commencer
- Lisez l'issue en entier, puis le guide de contribution du projet.
- Signalez en commentaire que vous la prenez — cela évite que deux personnes fassent le même travail.
- Forkez le dépôt et travaillez sur une branche.
- Ouvrez une pull request qui référence le numéro de l'issue.
Autres issues de OpenIPC/devourer
-
Difficulté 2/5 1-3 heures Accessibilité débutants 82/100
Les mainteneurs répondent en général sous 1 jour
-
Follow-ups left open by the 8822B fast bandwidth toggle fix (#584)Peut-être pris @josephnef l’a pris aujourd’hui. Ouverteenhancement
Difficulté 4/5 3-5 jours Accessibilité débutants 42/100
Les mainteneurs répondent en général sous 1 jour
-
Difficulté 5/5 Plus d'une semaine Accessibilité débutants 12/100
OpenIPC/devourer#579 · 1 commentaire ·
Les mainteneurs répondent en général sous 1 jour
-
enhancement
Difficulté 5/5 Plus d'une semaine Accessibilité débutants 12/100
Les mainteneurs répondent en général sous 1 jour
-
enhancement
Difficulté 5/5 Plus d'une semaine Accessibilité débutants 8/100
Les mainteneurs répondent en général sous 1 jour
Toutes les issues de OpenIPC/devourer
Issues similaires
-
Difficulté 2/5 1-3 heures Accessibilité débutants 72/100
Les mainteneurs répondent en général sous 1 jour
-
Needs-Triage
Difficulté 2/5 1-3 heures Accessibilité débutants 66/100
Les mainteneurs répondent en général sous 2 jours
-
issue: bug report
Difficulté 2/5 1-3 heures Accessibilité débutants 82/100
Les mainteneurs répondent en général sous 2 jours
-
cross-platform fix-now
Difficulté 2/5 1-3 heures Accessibilité débutants 76/100
Les mainteneurs répondent en général sous 1 jour
-
feature:index kind:crash status:confirmed triaged
Difficulté 2/5 1-3 heures Accessibilité débutants 77/100
clice-io/clice#1123 · 1 commentaire ·
Les mainteneurs répondent en général sous 1 jour