WinGet source update fails with 0x87E80034 - MSIX manifest deployment error

Offen
#6,594 0 Kommentare 0 Reaktionen 0 zugewiesene Personen Auf GitHub ansehen

Maintainer antworten meist innerhalb von 2 Tagen

Dieses Issue hat noch niemand übernommen.

Bewertung

Schwierigkeit
4/5
Geschätzter Aufwand
3-5 Tage
Anfängerfreundlichkeit
38/100
Issue-Typ
Bug
Klarheit
Größtenteils klar
Aktivitätsstatus
Aktiv
Tech-Stack
cpp
Bereich
backend, cli

Rechercherichtung

Start with the WinGet CLI source update path and its tests; the report does not name specific files or tests. Reproduce winget source update --name winget on the stated Windows 11 environment and trace the failure after the package download to the MSIX deployment error. Done means the source package installs and registers successfully so searches work.

Vom Indexierungsmodell aus dem Issue-Text verfasst.

Beschreibung

Issue-Bug
Relevant area(s)

WinGet CLI

Relevant command(s)

No response

Brief description of your issue

WinGet 1.29.380 consistently fails to update its default winget repository on Windows 11. The entire 3.62 MB source package downloads successfully, but the operation immediately reports "Cancelled". Manual installation of the Microsoft-signed source MSIX package fails with HRESULT 0x80073CF0 and underlying error 0x87E80034 (MsixvcStagingSession::GetManifestReader). The issue persists after resetting WinGet sources and App Installer, running DISM and SFC, restarting Windows, and verifying package integrity, signature, and folder permissions. Microsoft Store application updates work normally. No third-party antivirus is installed.

Steps to reproduce
  1. Open Windows PowerShell.
  2. Run: winget source update --name winget
  3. Wait for the 3.62 MB download to finish.
  4. WinGet reports 'Cancelled'.
  5. Running winget list reports that the winget source could not be updated or searched.
Expected behavior

WinGet should download, install, and register the repository source package successfully, allowing normal application searches, installations, and upgrades.

Actual behavior

WinGet downloads the entire 3.62 MB source package, then reports 'Cancelled'.

Manual installation using Add-AppxPackage fails with HRESULT 0x80073CF0.

Underlying deployment error:
MsixvcStagingSession::GetManifestReader failed with error 0x87E80034.

The failure persists after resetting WinGet sources and App Installer, running DISM and SFC, restarting Windows, and verifying package integrity, signature, and folder permissions.

Environment
[winget --info]
Windows Package Manager version: 1.29.380
Windows: Windows.Desktop version 10.0.26300.9711
System Architecture: X64
Package: Microsoft.DesktopAppInstaller version 1.29.380.0

Other software:
Microsoft Defender Antivirus (enabled)
Windows Firewall (enabled)
No third-party antivirus reported.
Microsoft Store works and successfully updated multiple applications.

WinGet source:
Name: winget
URL: https://cdn.winget.microsoft.com/cache
Type: Microsoft.PreIndexed.Package

Deployment failure:
HRESULT: 0x80073CF0
Underlying error: 0x87E80034
MsixvcStagingSession::GetManifestReader failed.
Vorherrschende Sprache
C++
Sterne
26.6k
Forks
1.8k
Ø Merge
3 T. 10 Std.
Gemergte PRs (30 T.)
41

Entwicklungsumgebung

Erste Schritte

  1. Lesen Sie das ganze Issue und danach den Beitragsleitfaden des Projekts.
  2. Schreiben Sie ins Issue, dass Sie es übernehmen — das erspart doppelte Arbeit.
  3. Forken Sie das Repository und arbeiten Sie in einem Branch.
  4. Öffnen Sie einen Pull Request, der die Issue-Nummer nennt.

Mehr aus microsoft/winget-cli

Alle Issues in microsoft/winget-cli

Ähnliche Issues

Weitere Issues zu C++

Neue Issues direkt in Ihr Postfach

Eine kurze Übersicht über anfängerfreundliche GitHub-Issues.