connection_lost() tears down the worker loop before notifying the application, so disconnect() races the teardown
Chưa có ai nhận issue này.
Đánh giá
- Độ khó
- 4/5
- Thời gian dự kiến
- 3-5 ngày
- Mức phù hợp với người mới
- 35/100
- Loại issue
- Lỗi
- Độ rõ ràng
- Khá rõ ràng
- Mức độ hoạt động
- Ít trao đổi
- Công nghệ
- python
- Lĩnh vực
- backend, networking
Hướng nghiên cứu
Start with bellows/uart.py, especially Gateway.connection_lost() and the connection_done callback that calls EventLoopThread.force_stop(). Read the nearby startup reset ordering comment and trace how EZSP.disconnect() reaches the gateway proxy. Done means the application can finish disconnect cleanup before the worker loop stops, with the reported reproduction no longer hanging.
Do mô hình lập chỉ mục viết ra từ nội dung của issue.
Mô tả
Summary
All the current work on ThreadsafeProxy teardown (#722, #727, #730, #739, #740, #741)
makes the failure graceful — return an awaitable, swallow the RuntimeError, log a
warning. None of it addresses why the proxy is being used against a dead loop in the first
place, which is an ordering problem one layer up in uart.py.
Gateway.connection_lost() resolves connection_done — which triggers
EventLoopThread.force_stop() — before it notifies the application that the connection
was lost:
def connection_lost(self, exc): # uart.py:67
...
if self._connection_done_future:
self._connection_done_future.set_result(exc) # :82 -> fires the :148 callback -> force_stop()
self._connection_done_future = None
...
self._api.connection_lost(exc) # :89 -> only now does the app find out
connection_done.add_done_callback(lambda _: thread.force_stop()) # :148
So the teardown of the loop is already in flight while :89 is still propagating upward
through EZSP.connection_lost → ControllerApplication.connection_lost → the
application's listener. By the time the application unwinds and calls
await self._ezsp.disconnect(), it is racing that teardown — and disconnect() has to go
through the proxy bound to exactly the loop being torn down.
Making the proxy fail gracefully turns a hang into a no-op, which is a real improvement,
but the disconnect still does not actually run. Flipping the order — notify the
application first, resolve connection_done after — would let the normal cleanup path
complete before the loop goes away, and would make the proxy's disconnected branches a
genuine edge case rather than the common path.
This hazard is in fact already documented a few lines above, for a different future
(uart.py:74-77):
# XXX: The startup reset future must be resolved with an error *before* the
# "connection done" future is completed: the secondary thread has an attached
# callback to stop itself, which will cause the a future to propagate a
# `CancelledError` into the active event loop, breaking everything!
That is the same mechanism — "the secondary thread has an attached callback to stop
itself" — recognised for _startup_reset_future but not for the application notification
at :89, which is also downstream of the same set_result at :82. Given that comment,
I may well be missing a constraint that forces the current order.
I am also fairly confident this is the original bug behind
home-assistant/core#88202 (2023), whose workaround zigpy/zha#628 removed in January
2026 on the assumption that "the underlying bellows issue has been resolved" — while the
PR author notes in the same thread that the original issue was never actually found.
uart.py has been heavily refactored since 2023 (407 → 151 lines), but this ordering has
survived every refactor untouched: the force_stop done-callback sat at :404 in
Feb 2023 (95c1bee) and sits at :148 today, with set_result(exc) still ahead of the
application notification in both.
Versions
| reproduced on | also verified present in | |
|---|---|---|
| bellows | 0.49.0 | 1.0.0 (uart.py byte-identical; thread.py ThreadsafeProxy unchanged) |
| zigpy | 1.2.2 | 2.1.0 |
| zha | 1.1.1 | 2.1.0 (CONF_USE_THREAD declared at application/const.py:76, zero references) |
| homeassistant | 2026.4.1 | dev (only components/zha/radio_manager.py:210 sets it, on the start_radio=False probe app) |
Coordinator: EFR32MG24 NCP reached over a raw TCP byte bridge (socket://<ip>:6638).
The bridge does no ASH framing, so nothing on my side interferes with the protocol.
All line numbers in this issue are from bellows 1.0.0 / dev.
What the application then hits
When the application unwinds and calls EZSP.disconnect():
async def disconnect(self): # ezsp/__init__.py:231
self.stop_ezsp()
if self._gw:
await self._gw.disconnect() # _gw is ThreadsafeProxy(gateway, worker_loop)
ThreadsafeProxy.func_wrapper (thread.py:96-107) then dispatches to the worker loop.
Depending on exactly how far force_stop() has progressed, there are three outcomes:
| worker loop state | is_closed() |
run_coroutine_threadsafe |
result | tracked in |
|---|---|---|---|---|
| closed | True |
not reached | returns bare None → await None → TypeError |
#722, #730 |
| closed mid-dispatch | False then closes |
raises RuntimeError |
exception at caller | #740, #741 |
| stopped, not yet closed | False |
does not raise | future never resolves → unbounded hang | not covered |
The third row is the one I hit, and it is the worst of the three because it is completely
silent — no exception, no log line, no retry. force_stop() schedules loop.stop();
loop.close() only happens afterwards in _thread_main's finally, so there is a real
window where the loop is unusable but reports is_closed() == False.
Self-contained reproduction of that window (Python 3.14, no bellows import required):
import asyncio, threading, time, contextlib
loop = asyncio.new_event_loop()
threading.Thread(target=lambda: (asyncio.set_event_loop(loop), loop.run_forever()),
daemon=True).start()
time.sleep(0.3)
loop.call_soon_threadsafe(loop.stop) # what force_stop() does
time.sleep(0.3)
print("is_closed:", loop.is_closed()) # False -> the guard lets it through
async def victim(): return "ran"
fut = asyncio.run_coroutine_threadsafe(victim(), loop) # does NOT raise
try:
print("got:", fut.result(timeout=3))
except TimeoutError:
print("HANG: never resolves; caller has no timeout")
with contextlib.suppress(Exception):
loop.close()
try:
asyncio.run_coroutine_threadsafe(victim(), loop)
except RuntimeError as e:
print("after close:", e)
is_closed: False
HANG: never resolves; caller has no timeout
after close: Event loop is closed
I have also left this as a comment on #741, since that PR states it closes out the last
members of this family and this variant slips past both its is_closed() check and its
except RuntimeError.
Evidence
The hang leaves a distinctive trace when the loop is finally closed and the un-run
coroutine is garbage collected:
WARNING (bellows.thread_0) [py.warnings] /usr/local/lib/python3.14/asyncio/base_events.py:744:
RuntimeWarning: coroutine 'SerialProtocol.disconnect' was never awaited
self._ready.clear()
base_events.py:744 is inside BaseEventLoop.close(): the coroutine object was still
unwrapped when the loop was closed.
To be precise, this warning on its own does not distinguish the hang from the
RuntimeError variant — in both cases call() has already constructed the coroutine and
it is later collected unused (my reproduction above emits it on both paths). What
identifies the hang in my case is what came with it: no exception anywhere, no
Retrying in … from config_entries, and ss -tn showing zero connection attempts from
the host for the full 90 s I sampled. The RuntimeError and TypeError variants both
surface an exception to the caller; this one surfaced nothing at all.
The TypeError variant has been reported by users as "NoneType errors", e.g.
home-assistant/core#147509 (SLZB-06 Ethernet coordinator), and is already tracked in #722.
Why USB coordinators appear unaffected
The code path is identical, but a USB serial device essentially never raises
connection_lost during normal operation, so this path is not exercised. Network
coordinators hit it on every disconnect — cable, reboot, power loss, DHCP change.
Reproduction
- EZSP coordinator over
socket://,use_threadleft at its default (True). - Cut power to the coordinator (do not close the TCP connection gracefully — a hard
power cut is the harsher and more realistic case). - Frequently — but not always — the application never reconnects. In Home Assistant the
config entry never leaves unload; no retries are scheduled and, in the hang variant,
nothing is logged at all.
Across the reboots I logged before finding the cause, the coordinator came back on its own
5 times out of 9. I would not read too much into the exact ratio (small sample, and I was
not controlling for which of the three variants fired), but it matches the intermittency
described in #88202 and reported by SLZB-06 users.
Verification that use_thread=False still fixes it
With use_thread=False, _connect() runs on the caller's loop, so
ThreadsafeProxy._obj_loop is the main loop, :100 (loop == curr_loop) is hit first,
and :102/:107 are unreachable. EventLoopThread is never created, so there is no
force_stop() at all.
Measured on the setup above (power cut, nothing touched by hand):
| event | t | delta |
|---|---|---|
| power cut | 17:59:15 | — |
| connection loss detected, first retry scheduled | 17:59:34 | 19 s |
backoff Retrying in 5 s / 10 s |
17:59:34 / :45 | — |
| coordinator back up | ≈17:59:50 | — |
| application reconnected on its own | ≈17:59:58 | ≈43 s total |
No never awaited warning, no failed unload. Same test with the default
use_thread=True is what produced the trace quoted above.
Suggested fix
The minimal change is ordering: notify the application before the
connection_done future is resolved, so the teardown callback at :148 cannot run
until the upper layers have finished with the proxy — extending the invariant that the
XXX comment quoted above already applies to _startup_reset_future.
To be clear about what I am not proposing: removing the UART thread outright was
already tried in #598 and reverted in #604, because serial-port read notifications depend
on the event loop and any loop slowdown stalls radio traffic. That reasoning is sound and
I am not asking to revisit it — the bug here is the teardown ordering, which is
orthogonal to whether the thread exists.
Alternatives, if the ordering is load-bearing for something I have missed:
- Have
EZSP.disconnect()short-circuit when the gateway's loop is no longer usable,
instead of awaiting through the proxy — at minimum,ThreadsafeProxy.func_wrapper
should not return a bareNonefrom a coroutine call site (:105), since that turns
into a confusingTypeErrorat theawait. - Give the
run_coroutine_threadsafepath at:107a timeout so a dead loop degrades
to an error rather than an unbounded hang. - Failing all of the above, restore the
use_thread=Falsedefault forsocket://
device paths thatzigpy/zha#628removed. Note this is narrower than #598: #604's
objection is specifically about serial fd read notifications, which does not apply to
a TCP transport with kernel-side buffering. It is not free either — it moves ASH ACK
timing onto the main loop, which is the same failure mode described in #628's comments
about the 2026.1.0 VAD CPU regression — but as a fallback it is strictly better than the
current unbounded hang.
Happy to test any patch against the reproduction above.
- Ngôn ngữ chính
- Python
- Star
- 221
- Fork
- 104
- Merge trung bình
- 5 ngày 15 giờ
- Pull request đã merge (30 ngày)
- 4
Chuẩn bị môi trường
Dự án này không cung cấp dev container, Dockerfile hay hướng dẫn đóng góp, nên bạn cần tự thiết lập môi trường: hãy bắt đầu từ README và xem hướng dẫn đóng góp lần đầu của chúng tôi để biết các bước chung.
Bắt đầu từ đâu
- Đọc hết issue, rồi đọc hướng dẫn đóng góp của dự án.
- Bình luận trên issue rằng bạn sẽ nhận — tránh hai người làm cùng một việc.
- Fork repository và làm thay đổi trên một nhánh.
- Mở pull request có tham chiếu số hiệu của issue.
Issue khác của zigpy/bellows
-
Độ khó 4/5 3-5 ngày Mức phù hợp với người mới 15/100
-
Stale NCP source route is never invalidated after SOURCE_ROUTE_FAILURE; end device unreachable until re-pairCó thể đã có người làm @puddly đã nhận 5 ngày trước. Đang mở
Độ khó 4/5 3-5 ngày Mức phù hợp với người mới 48/100
-
Độ khó 5/5 Hơn một tuần Mức phù hợp với người mới 35/100
-
Độ khó 4/5 3-5 ngày Mức phù hợp với người mới 48/100
-
ThreadsafeProxy can still raise `RuntimeError: Event loop is closed` — remaining check-then-use race after #727/#739Có thể đã có người làm @zigpy-review-bot đã nhận 119 ngày trước. Đang mở
Độ khó 3/5 1-2 ngày Mức phù hợp với người mới 35/100
Tất cả issue của zigpy/bellows
Issue tương tự
-
Độ khó 2/5 1-3 giờ Mức phù hợp với người mới 62/100
volcengine/OpenViking#8432 ·
Maintainer thường phản hồi trong vòng 1 ngày
-
Failed chat turns are passed to the follow-up rewrite as completed historyCó thể đã có người làm @hskhyl đã nhận hôm nay. Đang mở
Độ khó 2/5 1-3 giờ Mức phù hợp với người mới 72/100
NVIDIA/auto-ontology#683 · 1 bình luận ·
Maintainer thường phản hồi trong vòng 1 ngày
-
documentation task
Độ khó 2/5 1-3 giờ Mức phù hợp với người mới 62/100
-
Implement parse_url and accept http URLs for Pear backendCó thể đã có người làm @muskan-creates352 đã nhận hôm nay. Đang mở
Độ khó 2/5 1-3 giờ Mức phù hợp với người mới 78/100
fedora-infra/anitya#2231 ·
Maintainer thường phản hồi trong vòng 2 ngày
-
MarkdownDocSerializer.post_process escapes '\<' to '\<', rendering literal '<' in CommonMarkĐang mở
Độ khó 2/5 1-3 giờ Mức phù hợp với người mới 74/100
docling-project/docling-core#1067 ·
Maintainer thường phản hồi trong vòng 3 ngày