Start by comparing the reference checkpoint static_shell_compute/static_shell_slash.dcp with the routed checkpoints under examples/04_freq, examples/05_perf, and examples/06_dcmac. Run the reported pr_verify -full_check comparisons and inspect the NOC-Validation-16 address-size differences. Done means documenting whether the RP rebuild flow causes the mismatch and whether pr_verify is required before partial PDI generation.

Do mô hình lập chỉ mục viết ra từ nội dung của issue.

Mô tả

We observed a similar failure on our Alveo V80 with Vivado 2025.1. We also found a separate DFX compatibility issue through offline pr_verify.
Our setup uses a custom SLASH shell modified from the original PCIe Gen5 x8 configuration to PCIe Gen4 x16. The observations therefore come from a modified shell. Our V80 board failed while loading the 05_perf partial PDI, accroding to dmesg:

[Fri Sep 25 11:04:06 2026] ami: CRITICAL WARNING: cmd id: 234 timed out(timeout), hot reset is required
[Fri Sep 25 11:04:06 2026] ami 0000:25:00.0: ERROR           : Submitted command timed out
[Fri Sep 25 11:04:06 2026] ami: ERROR           : Failed to get the heartbeat msg!
[Fri Sep 25 11:04:06 2026] ami: ERROR           : AMC Heartbeat expired event received
[Fri Sep 25 11:04:07 2026] ami 0000:25:00.0: ERROR           : Logging thread error - invalid PCI data read!
[Fri Sep 25 11:04:08 2026] ami: CRITICAL WARNING: cmd id: 237 timed out(timeout), hot reset is required
[Fri Sep 25 11:04:08 2026] ami 0000:25:00.0: ERROR           : Submitted command timed out
[Fri Sep 25 11:04:08 2026] ami: ERROR           : Failed to get the heartbeat msg!
[Fri Sep 25 11:04:08 2026] ami: ERROR           : AMC Heartbeat expired event received
[Fri Sep 25 11:04:08 2026] slash_qdma 0000:25:00.1: QDMA PCI access lost; stopping error polling and hardware cleanup
[Fri Sep 25 11:04:09 2026] ami: ERROR           : FW_IF write request failed; 28
[Fri Sep 25 11:04:09 2026] ami 0000:25:00.0: ERROR           : Submitted command killed, abort.
[Fri Sep 25 11:04:09 2026] ami: ERROR           : Failed to get the heartbeat msg!
[Fri Sep 25 11:04:09 2026] ami: ERROR           : AMC Heartbeat expired event received
[Fri Sep 25 11:04:09 2026] ami: ERROR           : Heartbeat fail count above threshold! Raising fatal event...
[Fri Sep 25 11:04:09 2026] ami: ERROR           : AMC Heartbeat fatal event received, stopping GCQ...
[Fri Sep 25 11:04:23 2026] ami: ERROR           : No matching cid 234 found, unexpected response
[Fri Sep 25 11:04:31 2026] ami: ERROR           : No matching cid 237 found, unexpected response
  • 11:04:05: PDI download started, size 32,221,056 bytes.
  • 11:04:06–08: AMI reported heartbeat timeouts, QDMA reported PCI access lost, and the download failed with No such device.
  • 11:04:47: A subsequent reset failed at AMI_IOC_DEVICE_BOOT with Operation not permitted.
  • VRTD subsequently reported that the device did not exist.
pr_verify failures

We ran pr_verify -full_check between each region’s reference abstract shell DCP and its corresponding routed implementation DCP:

Example RP checked Reference NoC address size Implemented address size Result
04_freq slash 128 MiB 64 KiB Not compatible
05_perf slash 128 MiB 8 MiB Not compatible
06_dcmac slash 128 MiB 256 KiB Not compatible

All three slash checks failed with NOC-Validation-16.

ERROR: [Constraints 18-6214] NOC-Validation-16: Reconfigurable NOC instance top_i/slash/S_AXILITE_INI in checkpoint ~/SLASH/linker/slashkit/resources/static_shell_compute/static_shell_slash.dcp has address size 134217728, while the equivalent reconfigurable NOC instance top_i/slash/axi_noc_0/inst/M00_AXI_nsu/bd_2beb_M00_AXI_nsu_0_top_INST/NOC_NSU512_INST in checkpoint ~/SLASH/examples/05_perf/build/perf_hw.vbin.prj/slash_rm/slash_perf_hw.runs/impl_1/top_wrapper_routed.dcp has a different address size 8388608. In Dynamic Function Exchange flow, the equivalent reconfigurable NOC instance must have the same address size across configurations. 

Is this NoC address-size change a known issue in the RP rebuild flow, or is a different verification procedure required? It would also be useful to clarify whether pr_verify should be enforced before partial PDI generation.

Originally posted by @ZhangMZh in #225

Ngôn ngữ chính
Tcl
Star
54
Fork
26
Merge trung bình
2 ngày 20 giờ
Pull request đã merge (30 ngày)
6

Chuẩn bị môi trường

Bắt đầu từ đâu

  1. Đọc hết issue, rồi đọc hướng dẫn đóng góp của dự án.
  2. Bình luận trên issue rằng bạn sẽ nhận — tránh hai người làm cùng một việc.
  3. Fork repository và làm thay đổi trên một nhánh.
  4. Mở pull request có tham chiếu số hiệu của issue.

Issue khác của Xilinx/SLASH

Tất cả issue của Xilinx/SLASH

Issue tương tự

Thêm issue về Build System

Nhận issue mới trong hộp thư của bạn

Bản tóm tắt ngắn những issue GitHub phù hợp với người mới.