Alerts are sometimes not being fired when the logs meet the threshold criteria.

Đang mở
#3,307 0 bình luận 0 reaction 0 người được giao Xem trên GitHub

Maintainer thường phản hồi trong vòng 1 ngày

Chưa có ai nhận issue này.

Đánh giá

Độ khó
4/5
Thời gian dự kiến
3-5 ngày
Mức phù hợp với người mới
57/100
Loại issue
Lỗi
Độ rõ ràng
Khá rõ ràng
Mức độ hoạt động
Sôi nổi
Công nghệ
clickhouse, typescript
Lĩnh vực
observability

Hướng nghiên cứu

Start by reading packages/api/src/tasks/checkAlerts/index.ts, especially getScheduledWindowStart, and compare the current Start offset behavior with the tooltip’s promise of delaying evaluation for ingestion lag. Confirm the intended window semantics and add or run tests for a 2-minute offset on a 5-minute interval; done means delayed evaluation checks the intended earlier window and alerts are not missed due to ingestion lag.

Do mô hình lập chỉ mục viết ra từ nội dung của issue.

Mô tả

bug external Needs Feedback

What happened?

Hi, I'm using ClickStack and occasionally run into alerts that are not fired when they should be. This has only happened a few times over the past couple of months.

I think it may be caused by a log arriving after its window has been evaluated -- while investigating I found the Start offset setting under Advanced Settings on the alert, its tooltip says "Delays the start of each evaluation window by this many minutes. Useful when data is ingested with a lag," which sounds like exactly what I need.

However, from reading the source (getScheduledWindowStart in packages/api/src/tasks/checkAlerts/index.ts), I don't think it does this. With a 2 minute offset on a 5 minute interval, it shifts the window to e.g. 09:02:00 AM - 09:07:00 AM, rather than evaluating 09:00:00 AM - 09:05:00 AM two minutes later.

If my understanding is correct, I'm happy to put up a PR so the offset acts as a real evaluation delay for ingestion lag, as the tooltip describes, but wanted to check, can someone confirm the current behaviour isn't intended for a particular use case?

Steps to reproduce

  1. Create a saved query.
  2. Create an alert from that query which fires at >= 1 occurrences per 5-minute window.
  3. Sometimes the alert will not fire.

How are you running HyperDX?

ClickHouse Cloud.

Logs

The log's timestamp is 2026-10-06T23:09:46.990000000Z, which is only about 13 seconds before the window closed, again supporting the theory that it landed after the window was evaluated.

Image

However, the window is completely clear "OK" and no alert was ever sent.

Image

The timestamp on the log is 2026-10-06T23:09:46.990000000Z, so getting "close" to the window.

Ngôn ngữ chính
TypeScript
Star
10.1k
Fork
527
Merge trung bình
1 ngày 20 giờ
Pull request đã merge (30 ngày)
186

Chuẩn bị môi trường

Bắt đầu từ đâu

  1. Đọc hết issue, rồi đọc hướng dẫn đóng góp của dự án.
  2. Bình luận trên issue rằng bạn sẽ nhận — tránh hai người làm cùng một việc.
  3. Fork repository và làm thay đổi trên một nhánh.
  4. Mở pull request có tham chiếu số hiệu của issue.

Issue khác của ClickHouse/ClickStack

Tất cả issue của ClickHouse/ClickStack

Issue tương tự

Thêm issue về TypeScript

Nhận issue mới trong hộp thư của bạn

Bản tóm tắt ngắn những issue GitHub phù hợp với người mới.