add power factor
Maintainers usually reply within 1 day
Nobody has claimed this yet.
Assessment
- Difficulty
- 4/5
- Estimated time
- 3-5 days
- Newbie friendliness
- 35/100
Research direction
Start by locating the pre/post analysis that computes AEP and identifying which turbine signals are available to it. Determine whether reactive power or power factor can be incorporated, then define what counts as a significant change and how it should be reported. Done means the analysis includes the selected metric and warns when the post-period value changes materially from the pre-period value.
Written by the indexing model from the issue text.
Description
On a recent analysis I found that the test turbine was exporting more reactive power in the post period then the pre period (due to a change in the wind farm voltage control). The change was large enough that it affected the AEP results. wind-up should bring in reactive power or power factor as standard and warn if there is a significant change in post compared to pre.
- Dominant language
- Python
- Stars
- 29
- Forks
- 13
- Avg merge
- 1d 4h
- Merged PRs (30d)
- 27
Getting set up
This project ships no dev container, Dockerfile or contributing guide, so setting up is up to you: start from its README, and see our first-contribution guide for the general steps.
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from resgroup/wind-up
-
v1
Difficulty 2/5 1-3 hours Newbie friendliness 74/100
Maintainers usually reply within 1 day
-
enhancement
Difficulty 2/5 1-3 hours Newbie friendliness 62/100
Maintainers usually reply within 1 day
-
Convert the WeDoWind example to the v1 interfacePossibly taken A pull request linked to this issue is open or already merged. Openv1
Difficulty 4/5 Half a day Newbie friendliness 58/100
Maintainers usually reply within 1 day
-
Difficulty 4/5 3-5 days Newbie friendliness 45/100
Maintainers usually reply within 1 day
-
Difficulty 3/5 1-2 days Newbie friendliness 48/100
Maintainers usually reply within 1 day
All issues in resgroup/wind-up
Similar issues
-
eegprep-lean: set channel types from the Zarr group's channel_typePossibly taken @claude claimed this today. Open
Difficulty 2/5 1-3 hours Newbie friendliness 70/100
sccn/eegprep#668 · 1 comment ·
Maintainers usually reply within 1 day
-
Difficulty 2/5 1-3 hours Newbie friendliness 66/100
-
bug
Difficulty 2/5 1-3 hours Newbie friendliness 75/100
blacklanternsecurity/bbot#3679 ·
Maintainers usually reply within 2 days
-
Link Checker ReportOpenBot Type: Bug Type: Documentation
Difficulty 1/5 Under an hour Newbie friendliness 85/100
-
Difficulty 2/5 1-3 hours Newbie friendliness 80/100
speakeasy-api/speakeasy#2159 ·
Maintainers usually reply within 1 day