Direção de pesquisa
Start with Mirth.startup(), Mirth.shutdown(), and the shutdown-hook registration in Mirth.run(), then inspect the engine and database shutdown calls involved in the Derby path. Reproduce with a fresh Derby install, an invalid SCHEMA_INFO.VERSION, failed startup, and SIGTERM as described. Done means startup failure leaves no engine/database shutdown work that requires a connection, and the process exits promptly without writing the shutdown event; verify both Derby and PostgreSQL behavior where possible.
Escrita pelo modelo de indexação a partir do texto da issue.
Descrição
Summary
After a startup failure such as a MigrationException, the process keeps running (#498). Stopping it normally runs the JVM shutdown hook, which calls Mirth.shutdown() as if the server had started. That stops the engine, which reads from the database, and dispatches a "Server shutdown" event, which a separate listener thread writes to the EVENT table.
- Derby: the hook hangs. Startup already shut Derby down, so the engine waits for a pooled connection that never comes. The process has to be killed with SIGKILL.
- PostgreSQL: the process exits about 2 seconds after SIGTERM. With
log_statement = 'all', the only statements from the hook were a read-onlySELECT VALUEfromCONFIGURATION, run while stopping the engine. No "Server shutdown" event was written in two runs. The event is inserted by theAuditableEventListenerthread, so the JVM halting first is timing, not design; on a slower shutdown the insert could reach a database that startup refused to migrate.
MySQL, Oracle and SQL Server were not tested; they share the PostgreSQL path, because stopDatabase() only acts on Derby.
Steps to reproduce
With the default Derby database, from the server's install directory:
- Start a fresh install once so the database is created, then stop it (Ctrl+C once startup has finished):
./oieserver - With the server stopped, force a migration failure by setting a schema version this release doesn't know:
java -cp 'server-lib/database/*' org.apache.derby.tools.ij <<'EOF' connect 'jdbc:derby:appdata/mirthdb'; UPDATE SCHEMA_INFO SET VERSION = '99.0.0'; exit; EOF - Start the server again. Startup fails and the process keeps running (#498):
The migration fails with or without the fix for #496 (unrecognized schema version). Only the logged error differs../oieserver - Press Ctrl+C, or send SIGTERM to the Java process.
Expected
The process exits promptly without touching the database.
Actual (Derby)
The log shows shutting down mirth due to normal request and nothing more. The process was still running more than three minutes later, and SIGKILL was needed. The shutdown hook thread was parked in HikariCP (2.5.1) waiting for a connection:
HikariPool.getConnection
...
DefaultConfigurationController.getProperty(DefaultConfigurationController.java:1029)
DefaultConfigurationController.getChannelDependencies(DefaultConfigurationController.java:1132)
ChannelDependencyServerUtil.getOrderedChannels(ChannelDependencyServerUtil.java:30)
DonkeyEngineController.undeployChannels(DonkeyEngineController.java:462)
DonkeyEngineController.stopEngine(DonkeyEngineController.java:275)
Mirth.stopEngine(Mirth.java:461)
Mirth.shutdown(Mirth.java:417)
Mirth$ShutdownHook.run(Mirth.java:531)
No new row was written to EVENT on Derby, and SCHEMA_INFO was unchanged.
Cause
The MigrationException handler in Mirth.startup() calls stopDatabase() (which only shuts down Derby) and returns. The ShutdownHook registered in Mirth.run() then calls shutdown() unconditionally. shutdown() assumes a started server: it stops the engine, opens a database session to dispatch the "Server shutdown" event, and stops the web server, plugins and database.
On Derby the wait never ends because HikariConnectionPool sets connectionTimeout to 0, which HikariCP treats as no timeout. Once Derby is shut down, no connection can be created, so the hook waits forever.
A port conflict doesn't reach this path, because Mirth.run() returns before the hook is registered.
Suggested fix
Track whether startup completed, and have shutdown() skip stopping the engine and dispatching the event when it did not. Fix this together with #498. Making the process exit on a startup failure means calling System.exit, which runs this hook, so on Derby that fix would hang here unless this one lands with it.
🤖 Drafted with Claude Code
- Linguagem predominante
- Java
- Estrelas
- 227
- Forks
- 81
- Merge médio
- 2d 16h
- PRs com merge (30d)
- 12
Preparar o ambiente
- Inclui um Dockerfile ou arquivo Docker Compose
- Sem modelo de pull request
- Ler o guia de contribuição
Primeiros passos
- Leia a issue inteira e depois o guia de contribuição do projeto.
- Comente na issue dizendo que vai assumir — evita que duas pessoas façam o mesmo trabalho.
- Faça um fork do repositório e trabalhe em uma branch.
- Abra um pull request que referencie o número da issue.
Mais de OpenIntegrationEngine/engine
-
Outdated GitHub workflow action versionsTalvez já em andamento Um pull request vinculado a esta issue está aberto ou já foi mesclado. Aberta
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 68/100
OpenIntegrationEngine/engine#485 ·
Mantenedores costumam responder em até 1 dia
-
enhancement
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 62/100
OpenIntegrationEngine/engine#478 · 1 comentário ·
Mantenedores costumam responder em até 1 dia
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 68/100
OpenIntegrationEngine/engine#355 ·
Mantenedores costumam responder em até 1 dia
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 68/100
OpenIntegrationEngine/engine#347 ·
Mantenedores costumam responder em até 1 dia
-
Fix call-home in test runAberta
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 68/100
OpenIntegrationEngine/engine#313 ·
Mantenedores costumam responder em até 1 dia
Todas as issues de OpenIntegrationEngine/engine
Issues semelhantes
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 76/100
apache/rocketmq-dashboard#7250 ·
Mantenedores costumam responder em até 3 dias
-
Bug
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 67/100
ignatov/intellij-erlang#1093 ·
-
HttpMaxFrameSizeTest.sendOversizedMessageTest() passes silently when maxFrameSize is not enforcedAberta
Dificuldade 1/5 Menos de uma hora Facilidade para iniciantes 90/100
apache/activemq#2706 · 1 comentário ·
Mantenedores costumam responder em até 1 dia
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 72/100
federicoiosue/Omni-Notes#1032 ·
-
Dificuldade 2/5 1-3 horas Facilidade para iniciantes 78/100
unitycatalog/unitycatalog#2025 ·
Mantenedores costumam responder em até 4 dias