ArduPilot/ardupilot

EAHRS is performing duplicate temperature compenstation

Aberta

#25.792 aberto em 18 de dez. de 2023

 (6 comentários) (1 reação) (0 responsável)C++ (15.603 forks)batch import
BUGExternalAHRSgood first issue

Métricas do repositório

Stars
 (9.336 estrelas)
Métricas de merge de PR
 (Mesclagem média 26d 16h) (166 fundiu PRs em 30d)

Description

Bug report

Issue details

Certain devices exposed through EAHRS, like the MicroStrain7, supply data that is already temperature compenstated.

https://s3.amazonaws.com/files.microstrain.com/GQ7+User+Manual/external_content/dcp/Data/sensor_data/data/mip_field_sensor_scaled_mag.htm https://s3.amazonaws.com/files.microstrain.com/GQ7+User+Manual/external_content/dcp/Data/sensor_data/data/mip_field_sensor_scaled_accel.htm

When the External AHRS driver posts data to sensor libraries, they perform temperature compenstation on it again, as long as HAL_INS_TEMPERATURE_CAL_ENABLE is defined, which is based on board size.

Please describe the problem

This causes double temperature compensation, leading to incorrect values.

Proposed Solution Add bool is_temperature_compensated; to AP_ExternalARHS::ins_data_message_t, and then add the necessary hooks in AP_InertialSensor::handle_external(const AP_ExternalAHRS::ins_data_message_t &pkt) to stop doing temperature compensation if the supplied value is already temp-compensated.

See ryanf55:eahrs-precompensated-sensors for a prototype fix (WIP)

Version master 1e644d56a51806b63dcd68d5e6566ec0f10248fc

Platform [ x] All [ ] AntennaTracker [ ] Copter [ ] Plane [ ] Rover [ ] Submarine