[backward-conversion] Recognize templates
Maintainers usually reply within 1 day
Assessment
- Difficulty
- 5/5
- Estimated time
- Over a week
- Newbie friendliness
- 25/100
- Issue type
- Feature
- Clarity
- Needs clarification
- Activity status
- Stale
- Tech stack
- python
- Domain
- networking
Research direction
Start by tracing the backward-conversion path and how templates and local configuration values are represented. Compare first registration with later updates, focusing on matching configuration keys and template variables. Done means template values win on registration and unchanged local values are not duplicated during updates, with coverage for both cases.
Written by the indexing model from the issue text.
Description
There's an issue with the backward conversion which I did not consider in the beginning.
Imagine the situation in which the configuration of a device is converted to NetJSON and sent to an openwisp2 instance.
Case 1) First registration
The system gets a NetJSON containing the full configuration, which will be inserted in the config field, BUT will override any configuration present in templates that are either set as default or are set in a second step by a user.
Case 2) Updates
Imagine an already registered OpenWRT device. A local user logs in via SSH or luci and updates some configurations. Some magic trick then detects the configuration changes and sends the updated NetJSON full configuration to the server.
Without an appropriate mechanism, the configuration present in templates will be duplicated in the main config field
In short
The library needs to understand how to handle both cases, in the first, if same configuration keys are present both in the local conf and in templates, the templates win and the local conf values are discarded.
In the second case, local conf values are discarded only if they are equal to the same values present in the values of templates.
Challenges
I'm noting down challenges regarding this task.
Recognize variables
When a configuration is received, if the content of a configuration option matches the content of a variable in a template, it should be recognized as the template, not as a custom local configuration that needs to be stored.
- Dominant language
- Python
- Stars
- 389
- Forks
- 97
- Avg merge
- 1d 14m
- Merged PRs (30d)
- 14
Getting set up
- No Dockerfile or Docker Compose file
- Has a pull request template
- Read the contributing guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from openwisp/netjsonconfig
-
Difficulty 2/5 1-3 hours Newbie friendliness 62/100
openwisp/netjsonconfig#443 ·
Maintainers usually reply within 1 day
-
bug
Difficulty 2/5 1-3 hours Newbie friendliness 62/100
openwisp/netjsonconfig#131 ·
Maintainers usually reply within 1 day
-
wireguard_auto_client hardcodes IPv4 family/mask, and the ipv6 schema branch rejects template variablesMay be free again A pull request for this issue was closed without being merged. Open
Difficulty 3/5 1-2 days Newbie friendliness 72/100
openwisp/netjsonconfig#406 ·
Maintainers usually reply within 1 day
-
[bug] Property name of VXLAN interfaceMay be free again @SajalDevX claimed this 60 days ago, and no pull request is open. Openbug
Difficulty 3/5 1-2 days Newbie friendliness 48/100
openwisp/netjsonconfig#373 · 1 comment ·
Maintainers usually reply within 1 day
-
BATMAN-adv and 802.11s Mesh Interface SupportMay be free again A pull request for this issue was closed without being merged. Openenhancement
Difficulty 5/5 Over a week Newbie friendliness 30/100
openwisp/netjsonconfig#368 · 1 comment ·
Maintainers usually reply within 1 day
All issues in openwisp/netjsonconfig
Similar issues
-
bug
Difficulty 2/5 1-3 hours Newbie friendliness 72/100
ClickHouse/dbt-clickhouse#829 ·
Maintainers usually reply within 1 day
-
Difficulty 2/5 1-3 hours Newbie friendliness 76/100
Maintainers usually reply within 1 day
-
triage
Difficulty 2/5 1-3 hours Newbie friendliness 75/100
Maintainers usually reply within 3 days
-
Difficulty 2/5 1-3 hours Newbie friendliness 62/100
volcengine/OpenViking#8432 ·
Maintainers usually reply within 1 day
-
bug
Difficulty 2/5 1-3 hours Newbie friendliness 68/100
Maintainers usually reply within 1 day