[Bug]: FileSequence: CLI processes with different TMPDIR use separate sequence counters, sporadic Duplicate entry on oc_job_runs in 35.0.3 (after #65434/#65425)

オープン
#66,935 コメント 0 件 リアクション 0 件 担当者 0 名 GitHub で見る

メンテナーはふだん 1 日以内に返信

まだ誰も着手していません。

評価

難易度
4/5
見積もり時間
3〜5日
初心者へのやさしさ
22/100
issue の種類
バグ
明瞭さ
おおむね明確
活発さ
活発
技術スタック
linux, mysql, php

調査の方向性

Start with FileSequence and ITempManager::getTempBaseDir() to see how the counter directory is derived from TMPDIR and related settings, then look at JobRuns::started where the duplicate insert on oc_job_runs fails. Reproducing needs two CLI processes with different TMPDIR values. Done would mean both processes share one counter, or the duplicate is retried, with the behaviour covered by a test.

索引モデルが issue の本文から書いたものです。

説明

Summary

On Nextcloud 35.0.3.2 (which includes #65425, the fix for #65434), sporadic Duplicate entry '<id>' for key 'PRIMARY' errors on oc_job_runs still occurred, roughly 5 per day, always in OC\BackgroundJob\JobRuns::started called from cron.php. The cause was not the argument order but that two CLI processes of the same instance used different counter directories, because FileSequence derives its directory from the per-process temp base dir (TMPDIR etc.). After giving both processes the same TMPDIR, the errors stopped completely (0 in 7 days, ~35 expected).

Environment
  • Nextcloud 35.0.3.2, MariaDB, Linux
  • cron.php every 5 minutes from the crontab of the Nextcloud user, run with TMPDIR=/home/<user>/tmp/ (set in that crontab by the hosting panel, KeyHelp)
  • occ background-job:worker --interval=1 --stop_after=10m as a systemd service of the same user, without TMPDIR (so it falls back to /tmp)
  • Web requests use APCuSequence, only CLI processes use FileSequence
Cause

FileSequence keeps its counters in <temp base dir>/sfi_file_sequence_<instanceid>/seq-NNN.slots. The temp base dir comes from ITempManager::getTempBaseDir() (config tempdirectory, upload_tmp_dir, TMP, TEMP, TMPDIR, sys_get_temp_dir()).

So cron.php used /home/<user>/tmp/sfi_file_sequence_<id>/ and the worker used /tmp/sfi_file_sequence_<id>/: two independent counters for the same instance, same server id, same CLI bit. The worker creates about 17 job runs per second, so a cron start collides with a worker run in the same millisecond with a probability of about 1.7 %. Both then get sequence 0 and the second insert fails. With 288 cron starts per day this gives about 5 errors per day, which matches what we saw. All 9 rows we examined had cli=1, seq=0, and every error was at the :x5 cron start.

Evidence
  • The slot files in the cron temp dir changed only at the :x5 marks; the files in /tmp changed every second.
  • 9 errors between 13 Nov (update to 35.0.3.2) and 15 Nov 01:00.
  • On 15 Nov 10:59 the systemd unit got Environment=TMPDIR=/home/<user>/tmp/ (same as cron). Since then 0 errors in 7 days, and the /tmp counter directory is no longer written.
Workaround

Use the same temp directory for every CLI entry point (cron, systemd units, manual occ), or set 'tempdirectory' in config.php.

Suggestions

The coordination path should not depend on per-process environment variables. For example:

  • use a fixed directory below the data directory (or tempdirectory only), or
  • add a setup check that warns when CLI processes resolve different temp base dirs, or
  • treat a duplicate in JobRuns::started as retryable (generate a new id) instead of aborting the run.

Related: #65434 (closed, locked), #65425.

主要言語
PHP
スター
37.6k
フォーク
5.4k
平均マージ
1日 13時間
マージ済み PR(30日)
623

環境構築

Codespaces で開く

このプロジェクトの開発コンテナを、あなたの GitHub アカウントでブラウザ上に起動します。

はじめの一歩

  1. issue を最後まで読み、次にプロジェクトのコントリビューションガイドを読みます。
  2. 着手することを issue にコメントします — 二人が同じ作業をするのを防げます。
  3. リポジトリをフォークし、ブランチを切って変更します。
  4. issue 番号を参照したプルリクエストを送ります。

nextcloud/server のほかの issue

nextcloud/server の issue をすべて見る

似ている issue

PHP の issue をもっと見る

新しい issue をメールで受け取る

初心者向けの GitHub issue を短くまとめたダイジェスト。