Hacktoberfest 2026: le issue che i maintainer hanno segnato per ottobre, aperte e adatte ai principianti. Sfoglia le issue Hacktoberfest

Flaky e2e: gateway-fleet reads a worker's capacity before the worker has left starting

Aperta
#414 1 commento 0 reazioni 0 assegnatari Vedi su GitHub

I maintainer di solito rispondono entro 1 giorno

@V3RON ci sta già lavorando.

Dal 6/10/2026.

  • #421 di @V3RON — aperta

Valutazione

Difficoltà
4/5
Tempo stimato
1-2 giorni
Idoneità per principianti
48/100
Tipo di issue
Bug
Chiarezza
Specificata chiaramente
Stato di attività
Attiva
Stack tecnologico
typescript

Direzione di ricerca

Start in e2e/gateway-fleet.test.ts at waitForWorkers and iosLimit, then read src/gateway/worker-link.ts (#rebuildView, #refreshStarting) and the changesCapacityOrLeases filter to see why daemon.started never triggers a refresh. Triage must settle the product question (refresh on leaving starting) before the test fix, and an open PR (#421) already claims the work; done means waitForWorkers waits for capacity/catalog presence and CI passes under the CPU-load conditions described.

Scritto dal modello di indicizzazione a partire dal testo della issue.

Descrizione

bug:ready flaky-test

What fails

e2e/gateway-fleet.test.ts > "gateway fleet > two workers join, status aggregates them, a kill disconnects one, drain flags the other" fails with AssertionError: expected 0 to be greater than 0 at expect(iosLimit(joined[0])).toBeGreaterThan(0). Seen once in CI on PR #409 (run 37477061691).

Cause: a race on main, not in a PR

The test waits only for both workers to be connected, then reads capacity from that first view. A worker that dials the gateway while its daemon is still starting answers status.get with health and host only (#398), so the gateway builds its view without capacity (worker-link.ts #rebuildView -> #refreshStarting). The view stays without capacity until the next refresh, and none is triggered when the worker becomes running: daemon.started is not a lease./device./install event (changesCapacityOrLeases), so the next read is a device or lease event or the 30s periodic tick. The test's iosLimit falls back to 0.

Evidence

  • On origin/main (37188b5), unmodified: 6 of 6 runs of the file pass under CPU load (16 busy loops on 12 cores), 5 of 5 unloaded.
  • On origin/main with await new Promise((r) => setTimeout(r, 1500)) as the first line of convergeStartup in src/daemon/main.ts (a slower startup): 3 of 3 runs fail with this exact assertion (2 tests failed each time).
  • The window is the worker's startup time, so anything that lengthens startup (PR #409 adds a serial read, doctor pass and lease reconcile) makes it likelier. It is not specific to that PR.

Two things to decide in triage

  1. Product: should the gateway refresh a worker's view as soon as it leaves starting? Today a freshly joined worker takes no routed work for up to 30s after its startup ends if no device or lease event happens first (check FleetCoordinator/routing on a view with no catalog).
  2. Test: waitForWorkers in the file should wait for capacity (and catalog) to be present before the test reads it.
Lingua principale
TypeScript
Stelle
15
Fork
1
Merge medio
8h 23m
PR unite (30g)
136

Preparare l'ambiente

Questo progetto non fornisce container di sviluppo, Dockerfile né guida per i contributori, quindi l'ambiente è a tuo carico: parti dal suo README e consulta la nostra guida al primo contributo per i passaggi generali.

Come iniziare

  1. Leggi tutta la issue e poi la guida ai contributi del progetto.
  2. Commenta sulla issue per dire che te ne occupi tu — evita che due persone facciano lo stesso lavoro.
  3. Fai un fork del repository e lavora su un branch.
  4. Apri una pull request che faccia riferimento al numero della issue.

Altre issue di callstackincubator/simlock

Tutte le issue di callstackincubator/simlock

Issue simili

Altre issue su TypeScript

Ricevi le nuove issue nella tua casella

Un breve riepilogo di issue GitHub adatte ai principianti.