[New device support]: TS0601 from _TZE284_o82bxgpq

Aperta
#33,680 2 commenti 0 reazioni 0 assegnatari Vedi su GitHub

I maintainer di solito rispondono entro 1 giorno

Nessuno ha ancora preso questa issue.

Valutazione

Difficoltà
3/5
Tempo stimato
1-2 giorni
Idoneità per principianti
50/100
Tipo di issue
Funzionalità
Chiarezza
Abbastanza chiara
Stato di attività
Attiva
Stack tecnologico
typescript
Ambito
backend

Direzione di ricerca

Start by reading the Zigbee2MQTT external converter documentation and search the device definitions for similar TS0601 devices or the manufacturer name _TZE284_o82bxgpq. The report says all four relays are missing, but does not describe their behavior or provide working reference data, so gather device fingerprints and datapoint information before defining support. Done means the device exposes four controllable relays and their states update correctly.

Scritto dal modello di indicizzazione a partire dal testo della issue.

Descrizione

new device support
Link

https://ozon.ru/t/ivwF46p

Database entry

{"id":4,"type":"Router","ieeeAddr":"0xa4c138db9f67f564","nwkAddr":3164,"manufId":4417,"manufName":"_TZE284_o82bxgpq","powerSource":"Mains (single phase)","modelId":"TS0601","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[4,5,61184,0,60672],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65503":"X��2\u0013X��2eY��2\u0012w��2e","65506":56,"65508":0,"modelId":"TS0601","manufacturerName":"_TZE284_o82bxgpq","powerSource":1,"zclVersion":3,"appVersion":78,"stackVersion":0,"hwVersion":1,"dateCode":""}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":78,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{},"lastSeen":1794487217458}

Zigbee2MQTT version

2.14.3 (unknown)

External definition
export default {
    zigbeeModel: ['TS0601'],
    model: 'TS0601',
    vendor: '_TZE284_o82bxgpq',
    description: 'Automatically generated definition',
    extend: [],
};
What does/doesn't work with the external definition?

Nothing works. There is no display or control of all 4 relays.

Notes

software_build_id: undefined
date_code: ``
endpoints:

{"1":{"bindings":[],"clusters":{"input":["genGroups","genScenes","manuSpecificTuya","genBasic","60672"],"output":["genOta","genTime"]},"configured_reportings":[],"scenes":[]},"242":{"bindings":[],"clusters":{"input":[],"output":["greenPower"]},"configured_reportings":[],"scenes":[]}}
Lingua principale
TypeScript
Stelle
15.8k
Fork
2.1k
Merge medio
1g 6h
PR unite (30g)
38

Preparare l'ambiente

Apri in Codespaces

Avvia il container di sviluppo del progetto nel browser, con il tuo account GitHub.

Come iniziare

  1. Leggi tutta la issue e poi la guida ai contributi del progetto.
  2. Commenta sulla issue per dire che te ne occupi tu — evita che due persone facciano lo stesso lavoro.
  3. Fai un fork del repository e lavora su un branch.
  4. Apri una pull request che faccia riferimento al numero della issue.

Altre issue di Koenkk/zigbee2mqtt

Tutte le issue di Koenkk/zigbee2mqtt

Issue simili

Altre issue su TypeScript

Ricevi le nuove issue nella tua casella

Un breve riepilogo di issue GitHub adatte ai principianti.