driver: Bituo SPM01R (SPM01R FLEX) single-phase Modbus energy meter
Maintainers usually reply within 1 day
Nobody has claimed this yet.
Assessment
- Difficulty
- 4/5
- Estimated time
- 3-5 days
- Newbie friendliness
- 25/100
- Issue type
- Feature
- Clarity
- Clearly specified
- Activity status
- Active
- Tech stack
- nodejs, typescript
- Domain
- embedded-iot
Research direction
Start from packages/driver-ex9em and packages/driver-or-we-516, plus docs/NEW-PACKAGE.md, to copy the package layout and see how readFloatBE decoding and DEFAULT_CONFIG/SUPPORTED_CONFIG are done. Create packages/driver-spm01r with src/index.ts and src/index.test.ts, write the mocked-transport tests first, and register the package in the root jest.config.js and tsconfig.json. Done when npm test, lint, typecheck and build pass with at least 95% coverage, and the register map is confirmed on real hardware.
Written by the indexing model from the issue text.
Description
Device information
- Manufacturer: Bituo Technik
- Model: SPM01R FLEX, order code SPM01-D2M1 (the shop used to call it SPM01/M1). The same user guide also covers the 3-phase SPM02R, which is out of scope here; it could be added later as a second device in the same package.
- Device type: energy meter, 1 phase + N, 63 A, built-in current sensor (the live wire passes through a hole in the housing). RS-485 is 4 kV isolated. It is powered from its own L and N cables (220-240 VAC, at most 2 VA).
- Price (for reference): USD 42.25 in the maker's shop, seen 2026-10-14: https://shop.bituo-technik.com/products/spm01-flex-miniature-energy-meter
Register documentation
- Link to official register map: the register list is in the user guide (V1.2, page "Modbus Register List"): https://downloads.bituo-technik.com/User-Guide/SPM01R02R-All-in-One_User-Guide_ENCN.pdf
- Product docs: https://docs.bituo-technik.com/product-document/spm-series/spm01r-flex
- Datasheet: https://downloads.bituo-technik.com/Datasheet/SPM01R-FLEX-All_Datasheet_EN.pdf
- (All seen 2026-10-14. The older register guide PDF on the maker's main site now returns 404, so use the user guide above. Following the
driver-ex9emexample, the PDF can be kept inpackages/driver-spm01r/docs/, if the licence allows. Otherwise link only.)
Function codes 03 (read holding) and 04 (read input) both return the same data. Float32 is big-endian (ABCD), 2 registers each. Addresses are as printed in the guide.
Data points to implement (single-frame block, registers 20000-20023, readable in one request of 24 registers):
| Register | Hex | Type | Size | Encoding | Description | Unit in guide | Scale / driver output | Suggested data point id |
|---|---|---|---|---|---|---|---|---|
| 20000 | 0x4E20 | input/holding | 2 | float32be | Voltage | V | x1, V |
voltage |
| 20002 | 0x4E22 | input/holding | 2 | float32be | Current | A | x1, A |
current |
| 20004 | 0x4E24 | input/holding | 2 | float32be | Active power | kW | x1000, W |
active_power |
| 20006 | 0x4E26 | input/holding | 2 | float32be | Power factor | none | x1 | power_factor |
| 20008 | 0x4E28 | input/holding | 2 | float32be | Frequency | Hz | x1, Hz |
frequency |
| 20010 | 0x4E2A | input/holding | 2 | float32be | Import active energy (can be reset) | kWh | x1, kWh |
import_active_energy |
| 20012 | 0x4E2C | input/holding | 2 | float32be | Export active energy (can be reset) | kWh | x1, kWh |
export_active_energy |
| 20014 | 0x4E2E | input/holding | 2 | float32be | Total (absolute) active energy | kWh | x1, kWh |
total_active_energy |
| 20016 | 0x4E30 | input/holding | 2 | float32be | Import active energy, non-resettable | kWh | x1, kWh |
total_import_active_energy |
| 20018 | 0x4E32 | input/holding | 2 | float32be | Export active energy, non-resettable | kWh | x1, kWh |
total_export_active_energy |
| 20020 | 0x4E34 | input/holding | 2 | float32be | Total active energy, non-resettable | kWh | x1, kWh |
total_active_energy_nonresettable |
| 20022 | 0x4E36 | input/holding | 2 | float32be | Apparent power | kVA | x1000, VA |
apparent_power |
Names follow driver-ex9em (voltage, current, active_power, apparent_power, power_factor, frequency). The energy names are only a suggestion; choose what is consistent with the other energy-meter drivers.
Settings registers (read/write, FC 03/04 read, 06/10 write), mark these pollType: 'on-demand':
| Register | Hex | Type | Description | Values |
|---|---|---|---|---|
| 6000 | 0x1770 | uint16 | Modbus address | 1-247 (default 247) |
| 6001 | 0x1771 | uint16 | Baud rate | 0=9600, 1=2400, 2=4800, 3=9600 (default), 4=19200, 5=38400 (the guide lists 0 and 3 both as 9600; check on the device) |
| 6002 | 0x1772 | uint16 | Parity and stop bits | 0=N81 (default), 1=E81, 2=O81, 3=N82 |
Other registers in the guide (not data points, optional):
- Product identification, UTF-8 strings: 100 meter type ("SPM01" or "SPM02"), 120 product ID, 125 serial number, 130 hardware version, 135 firmware version. Meter type could be used for auto-detection.
- 10000 (0x2710), FC 06, write 0x5055: blinks the LED for 15 s, to find the device in a panel.
- 10001 (0x2711), FC 06, write 0x51AA: resets the resettable energy counters. Do not expose as a normal writable data point.
- 30000 (0x7530), FC 10, broadcast address 0, write
0x55AA+ new address (1-246): only the meter whose reset button is currently pressed accepts it. Probably out of scope. - A full per-register table also exists at 1000-1076 (same values as float32, laid out for the 3-phase SPM02R; SPM01R fills only phase A, frequency and energy: V 1000, A 1006, W 1012, VA 1024, PF 1030, Hz 1052, import 1054, export 1056, absolute 1058). The single-frame block above is simpler and is marked "SPM01R only" in the guide.
Device defaults
- Default slave ID: 247
- Default baud rate: 9600
- Default parity: none
- Default stop bits: 1 (8 data bits)
- A press of 5 seconds on the reset button restores address, baud rate and format to these defaults.
Device limitations
- Maximum registers per read request: not stated. The single-frame block is 24 registers, which the maker designed to be read in one request.
- Forbidden/reserved register ranges: none stated. Registers 10001 (energy reset) and 30000 (broadcast address) are write-only commands; never read them in a poll.
- Required delays between requests: not stated.
- Other quirks:
- The guide prints active and apparent power in kW / kVA. Confirm the scale on a real device with a known load before release (a 100 W load should read 0.1).
- The minimum current for correct reading is not stated for this model (the Zigbee sibling is quoted at 50 mA start current). The characterisation run should include a low load (below 0.5 A).
- Measures energy in both directions; "forward" is the direction of the arrow printed on the housing.
Device profile (recommended)
A device profile from real hardware is not available yet. The household plans to buy one unit; a profile will be attached then (ya-modbus-profile). Until then the driver is written from the vendor's register list and should say so in the README.
- Device profile attached
Additional context
Use case: measuring the real power draw of a small server and its network switch on a UPS output, then feeding it to MQTT through ya-modbus-bridge. The household's existing homy stack currently reads its meters with its own modbus-serial driver files; it will use this driver if it has moved to ya-modbus by the time the meter is installed.
Notes from earlier tests of other drivers with the bridge, that apply here as well:
- The bridge polls every data point, including
pollType: 'on-demand'ones, and one failed read drops the whole poll (#599). So only list registers that are verified on hardware; an unverified register can silence the whole device (#598). - Use Node 22 for serial work (#507).
Layout and approach (follows the existing drivers, e.g. packages/driver-or-we-516 and packages/driver-ex9em)
- New package
packages/driver-spm01r, npm name@ya-modbus/driver-spm01r(lowercase letters, digits and hyphens only; the bridge rejects other names). - Files, copied from
packages/driver-ex9em(single-phase meter,README.md,docs/,jest.config.cjs,tsconfig.*.json,package.json; start fromdocs/NEW-PACKAGE.md) andpackages/driver-or-we-516(float32 reading withreadFloatBE,AGENTS.md/CLAUDE.md):src/index.tsexportscreateDriver,DEFAULT_CONFIG(247, 9600, none, 8, 1) andSUPPORTED_CONFIG(baud rates 2400, 4800, 9600, 19200, 38400; parity none/even/odd; address 1-247).src/index.test.tsnext to it, with a mockedTransport.package.jsonwith keywords includingya-modbus-driver,enginesfield, repositorydirectoryset to the new package.README.mdwith device info, defaults, usage and the data point table, and the note that the register list comes from the vendor and was (or was not yet) confirmed on hardware.
- Read the 24-register block with one
transport.readHoldingRegisters(20000, 24)call (or input registers; both work) and decode all configured data points from the same buffer inreadDataPoints, asdriver-or-we-516does. - Output power in W and VA (the register values times 1000). Use
V,A,W,VA,Hz,kWhunits. - Register the package in the root
jest.config.js(projects) and roottsconfig.json(references), as the other drivers are.
Done when
-
packages/driver-spm01rexists with the layout above,createDriver,DEFAULT_CONFIGandSUPPORTED_CONFIG. - Tests are written first with a mocked transport and cover: every data point decode (float32 big-endian fixtures, including the kW to W and kVA to VA scale), the single 24-register read in
readDataPoints, unknown data point errors, read-only errors, writes of address, baud rate and parity (valid and invalid values), and a cross-check thatDEFAULT_CONFIGis insideSUPPORTED_CONFIG. - Coverage is at least 95 % on all metrics, as
docs/NEW-PACKAGE.mdrequires. - The package is added to the root
jest.config.jsandtsconfig.json;npm testfrom the root runs it. -
npm run build,npm run lint,npm run typecheck,npm run validate:packagesandnpm run validate:dist-importspass. -
README.mdin the package is written; the driver is listed in the root README next to the other drivers. - Config registers (address, baud rate, parity) are
pollType: 'on-demand'; the reset-energy and broadcast-address registers are not exposed as normal data points. - A real-device check is done with
npx ya-modbus read(andya-modbus-profileif possible): values compared with a known load, the kW/kVA scale confirmed, and the result noted on this issue. The README then says the driver is hardware-verified. - If the emulator is used by other drivers' tests, an emulator-based test with the SPM01R register map is added too (
@ya-modbus/emulator); if not, mocked-transport tests are enough. - The first release goes out through the normal release process (conventional commit
feat(driver-spm01r): ..., trusted-publisher setup perdocs/NEW-PACKAGE.md).
- Dominant language
- TypeScript
- Stars
- 3
- Forks
- 0
- Avg merge
- 13h 46m
- Merged PRs (30d)
- 58
Getting set up
- No Dockerfile or Docker Compose file
- Has a pull request template
- Read the contributing guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from groupsky/ya-modbus
-
Difficulty 2/5 1-3 hours Newbie friendliness 78/100
Maintainers usually reply within 1 day
-
Difficulty 1/5 Under an hour Newbie friendliness 88/100
Maintainers usually reply within 1 day
-
Difficulty 2/5 1-3 hours Newbie friendliness 82/100
Maintainers usually reply within 1 day
-
codex-ok
Difficulty 2/5 1-3 hours Newbie friendliness 78/100
Maintainers usually reply within 1 day
-
codex-ok type:bug
Difficulty 2/5 1-3 hours Newbie friendliness 85/100
Maintainers usually reply within 1 day
All issues in groupsky/ya-modbus
Similar issues
-
enhancement UX
Difficulty 2/5 1-3 hours Newbie friendliness 67/100
online-go/online-go.com#4000 ·
Maintainers usually reply within 1 day
-
enhancement good first issue
Difficulty 2/5 1-3 hours Newbie friendliness 82/100
Maintainers usually reply within 1 day
-
Difficulty 2/5 1-3 hours Newbie friendliness 75/100
SnosMe/awakened-poe-trade#1976 ·
-
[BUG]Openbug
Difficulty 2/5 1-3 hours Newbie friendliness 63/100
jonp-h/TillerQuest#319 ·
-
Difficulty 2/5 1-3 hours Newbie friendliness 82/100
terrazzoapp/terrazzo#902 ·