DNS broken after kernel update

Ouverte
#1,108 0 commentaires 0 réactions 0 personnes assignées Voir sur GitHub

Les mainteneurs répondent en général sous 1 jour

Personne n'a encore pris cette issue.

Évaluation

Difficulté
4/5
Temps estimé
3-5 jours
Accessibilité débutants
35/100
Type d'issue
Bug
Clarté
À clarifier
Activité
Active
Stack technique
linux, python
Domaine
devops

Piste de recherche

The report names no mintupdate files, tests, or entry points. Start by checking whether DNS failure after the kernel update can be reproduced and whether mintupdate logs show it changing resolver configuration; compare behavior with FortiClient running and with the earlier kernel update. Done means identifying a reproducible connection to mintupdate or narrowing the cause to another component.

Rédigé par le modèle d'indexation à partir du texte de l'issue.

Description

BUG

Describe the bug
After upgrading via the Update manager to kernel 7.0.0-42, and rebooting internet was not working.

This worked: ping -c 4 8.8.8.8
This failed: ping -c 4 google.com

This fixed the problem:
sudo rm -f /etc/resolv.conf
sudo bash -c 'echo "nameserver 8.8.8.8" > /etc/resolv.conf'
sudo bash -c 'echo "nameserver 1.1.1.1" > /etc/resolv.conf'

During the update and starting the reboot i had a VPN (forticlient) open. I don't know if that caused the issue.
I did had this problem a previous kernel update.

Distribution:
Linux Mint 22.3 - Cinnamon 64-bit
7.0.0-42-generic

Software version:
7.1.4

Logs:
2026.10.29@08:30 ++ Launching Update Manager
2026.10.29@08:30 ++ Initial refresh will happen in 0 day(s), 0 hour(s) and 10 minute(s)
2026.10.29@08:30 ++ Inhibited power management
2026.10.29@08:30 ++ Checking for updates
2026.10.29@08:30 ++ System is up to date
2026.10.29@08:30 ++ Refresh finished
2026.10.29@08:30 ++ Resumed power management
2026.10.29@08:40 ++ Update Manager window is open; skipping initial refresh
2026.10.29@08:40 ++ Auto refresh will happen in 0 day(s), 0 hour(s) and 1 minute(s)
2026.10.29@08:41 ++ Update Manager window is open; delaying auto refresh by 60s
2026.10.29@08:42 ++ Auto refresh will happen in 0 day(s), 0 hour(s) and 1 minute(s)
2026.10.29@08:43 ++ Update Manager window is open; delaying auto refresh by 60s
2026.10.29@08:44 ++ Auto refresh will happen in 0 day(s), 0 hour(s) and 1 minute(s)
2026.10.29@08:45 ++ Update Manager window is open; delaying auto refresh by 60s
2026.10.29@08:46 ++ Auto refresh will happen in 0 day(s), 0 hour(s) and 1 minute(s)
2026.10.29@08:47 ++ Update Manager window is open; delaying auto refresh by 60s
2026.10.29@08:48 ++ Auto refresh will happen in 0 day(s), 0 hour(s) and 1 minute(s)
2026.10.29@08:49 ++ Update Manager window is open; delaying auto refresh by 60s
2026.10.29@08:50 ++ Auto refresh will happen in 0 day(s), 0 hour(s) and 1 minute(s)
2026.10.29@08:51 ++ Update Manager is in tray mode; performing auto refresh
2026.10.29@08:51 ++ Auto refresh will happen in 0 day(s), 0 hour(s) and 1 minute(s)
2026.10.29@08:51 ++ Inhibited power management
2026.10.29@08:51 ++ Refreshing cache
2026.10.29@08:51 ++ Refreshing cache for Cinnamon updates
2026.10.29@08:51 ++ Refreshing cache for Flatpak updates
2026.10.29@08:52 ++ Checking for updates
2026.10.29@08:52 ++ System is up to date
2026.10.29@08:52 ++ Refresh finished
2026.10.29@08:52 ++ Resumed power management
2026.10.29@08:52 ++ Update Manager is in tray mode; performing auto refresh
2026.10.29@08:52 ++ Auto refresh will happen in 0 day(s), 1 hour(s) and 59 minute(s)
2026.10.29@08:52 ++ Inhibited power management
2026.10.29@08:52 ++ Refreshing cache
2026.10.29@08:52 ++ Refreshing cache for Cinnamon updates
2026.10.29@08:52 ++ Refreshing cache for Flatpak updates
2026.10.29@08:53 ++ Checking for updates
2026.10.29@08:53 ++ Refresh finished
2026.10.29@08:53 ++ System is up to date
2026.10.29@08:53 ++ Resumed power management

Additional context
A running FortiClient VPN 7.4.3.5411

Langage dominant
Python
Étoiles
428
Forks
196
Merge moyen
16 h 9 min
PR mergées (30 j)
1

Préparer son environnement

Ce projet ne fournit ni conteneur de développement, ni Dockerfile, ni guide de contribution : l'installation est à votre charge. Commencez par son README, et consultez notre guide de la première contribution pour les étapes générales.

Par où commencer

  1. Lisez l'issue en entier, puis le guide de contribution du projet.
  2. Signalez en commentaire que vous la prenez — cela évite que deux personnes fassent le même travail.
  3. Forkez le dépôt et travaillez sur une branche.
  4. Ouvrez une pull request qui référence le numéro de l'issue.

Autres issues de linuxmint/mintupdate

Toutes les issues de linuxmint/mintupdate

Issues similaires

Plus d'issues Python

Recevez les nouvelles issues par e-mail

Un résumé court des issues GitHub adaptées aux débutants.