Docking: a structure added to a Vina calculation should be placed clear of the receptor and taken as the ligand

Ouverte
#1,297 0 commentaires 0 réactions 0 personnes assignées Voir sur GitHub

Personne n'a encore pris cette issue.

Évaluation

Difficulté
4/5
Temps estimé
3-5 jours
Accessibilité débutants
48/100
Type d'issue
Fonctionnalité
Clarté
Clairement spécifiée
Activité
Active
Stack technique
c

Piste de recherche

Start by tracing File > Add Structure from File and how it updates the Vina calculation's structure and selection; inspect the handling of ES.Runtype.Docking.LigandAtoms and the camera framing around that path. Check related issues #1296, #455, and #962 for context. Done means added atoms are offset clear of the receptor, both structures are framed, and those atoms are selected and set as the ligand.

Rédigé par le modèle d'indexation à partir du texte de l'issue.

Description

enhancement

A Vina calculation holds one structure, and the receptor/ligand split is by atom index inside it (ES.Runtype.Docking.LigandAtoms). So a ligand that was not in the receptor's file has to be merged into that structure, and File > Add Structure from File is the only route. It works, but two things are left to the user.

Placement. The added molecule keeps the coordinates it had in its own file. For a molecule drawn in the Builder those are arbitrary relative to the protein: it lands far away, or inside it. Vina itself does not care (the receptor is rigid and the ligand is placed at random inside the search box), but the viewer shows a protein with a molecule buried in it or off at the edge of the scene, which reads as an error.

Proposed: when a structure is added to a calculation whose code is Vina, offset the added atoms clear of the receptor's bounding box and frame the camera so both are visible.

Ligand atoms. docking.pl would pick the added molecule anyway - with a polymer present the ligand is the largest non-polymer molecule (#962) - but the field stays empty and the choice is only visible in the Verify output. vinaBoxFromSelection fills the field only when the selection is exactly one residue of class RES_OTHER, which a drawn molecule is not.

Proposed: set ES.Runtype.Docking.LigandAtoms to the added atoms directly, and leave them selected, so the box tool can be used on them or on the pocket immediately afterwards.

Related: #1296 (the box is then still automatic and still wrong), #455, #962.

Langage dominant
C
Étoiles
10
Forks
8
Merge moyen
6 h 32 min
PR mergées (30 j)
1

Préparer son environnement

Ce projet ne fournit ni conteneur de développement, ni Dockerfile, ni guide de contribution : l'installation est à votre charge. Commencez par son README, et consultez notre guide de la première contribution pour les étapes générales.

Par où commencer

  1. Lisez l'issue en entier, puis le guide de contribution du projet.
  2. Signalez en commentaire que vous la prenez — cela évite que deux personnes fassent le même travail.
  3. Forkez le dépôt et travaillez sur une branche.
  4. Ouvrez une pull request qui référence le numéro de l'issue.

Autres issues de FriendsofECCE/ECCE

Toutes les issues de FriendsofECCE/ECCE

Issues similaires

Plus d'issues C

Recevez les nouvelles issues par e-mail

Un résumé court des issues GitHub adaptées aux débutants.