Describe the Bug
When a machine uses an OEM placeholder serial number (e.g., System Serial Number), its fingerprint is not unique. As a result, two PCs of the same model generate the same fingerprint.
When a second PC signs in using the same Pangolin user account, device approval is not triggered, and the second PC receives the same OLM as the first PC. This causes both devices to share the same OLM, resulting in their WireGuard peers overwriting each other and disrupting the connection.
Environment
- OS Type & Version: Windows 11 (Any build)
- Pangolin Version: 1.26
- Edition (Community or Enterprise): Any
- Gerbil Version: 1.6.0
- Traefik Version: 3.7.13
- Newt Version: 1.20
- Client Version: 0.16.0
To Reproduce
- Use two PCs of the same model whose BIOS serial is a placeholder (
System Serial Number,To Be Filled By O.E.M.,Default string, ...). - Install the client on PC A, sign in as user X, connect.
- Install the client on PC B, sign in as the same user X, connect.
AI Disclosure
No AI used in writing this bug report.
Expected Behavior
PC B gets its own OLM, appears as a second device, and requires device approval. Both PCs remain connected.
- Dominant language
- Go
- Stars
- 26
- Forks
- 10
- Avg merge
- 5h 49m
- Merged PRs (30d)
- 12
Getting set up
- No Dockerfile or Docker Compose file
- Has a pull request template
- Read the contributing guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from fosrl/windows-linux
-
Difficulty 1/5 Under an hour Newbie friendliness 90/100
fosrl/windows-linux#91 ·
Maintainers usually reply within 1 day
-
bug needs investigating
Difficulty 3/5 1-2 days Newbie friendliness 40/100
fosrl/windows-linux#90 · 2 comments ·
Maintainers usually reply within 1 day
-
Windows client tries to connect to Pangolin client tunnel port over IPv6 on an IPv4-only networkOpen
Difficulty 3/5 1-2 days Newbie friendliness 56/100
fosrl/windows-linux#88 · 6 comments ·
Maintainers usually reply within 1 day
-
enhancement
Difficulty 5/5 Over a week Newbie friendliness 25/100
fosrl/windows-linux#84 ·
Maintainers usually reply within 1 day
-
Windows creates a new network connection/interface on every connectMay be free again @oschwartz10612 claimed this 201 days ago, and no pull request is open. Openbug
fosrl/windows-linux#37 · 3 comments · 1 assignee ·
Maintainers usually reply within 1 day
All issues in fosrl/windows-linux
Similar issues
-
bug Web API
Difficulty 2/5 1-3 hours Newbie friendliness 78/100
Maintainers usually reply within 1 day
-
Difficulty 2/5 1-3 hours Newbie friendliness 72/100
-
Difficulty 2/5 1-3 hours Newbie friendliness 78/100
kubevela/terraform-controller#423 ·
Maintainers usually reply within 1 day
-
bug
Difficulty 2/5 1-3 hours Newbie friendliness 78/100
Maintainers usually reply within 1 day
-
Difficulty 2/5 1-3 hours Newbie friendliness 64/100
kubernetes-sigs/kubebuilder#6187 ·
Maintainers usually reply within 1 day