Side findings - Stop-Function without return, a warning that never throws, certificate files on PowerShell 7 and smaller defects in 10 commands
Los mantenedores suelen responder en 2 días
Nadie ha tomado este issue todavía.
Evaluación
- Dificultad
- 4/5
- Tiempo estimado
- 3-5 días
- Aptitud para principiantes
- 35/100
Línea de trabajo
The issue lists defects across several commands and names relevant locations, including tests/Get-DbaComputerCertificate.Tests.ps1:28. Start by reading the affected command and its existing tests, then reproduce one defect against development 900ba0347 (v2.9.1). Add a regression test that fails on the old behavior; done means the selected defect is fixed and its test passes.
Escrito por el modelo de indexación a partir del texto del issue.
Descripción
Defects found while going through the notes of the last weeks' work. Each one is checked against development 900ba0347 (v2.9.1); the line numbers are from there. None of them is in an open pull request. The plan is one fix per command, with a test that fails on the old code where the defect can be shown.
Defects
- Get-XpDirTreeRestoreFile (private, called by Get-DbaBackupInformation and so by Restore-DbaDatabase), lines 51 and 62-67: three
Stop-Functioncalls withoutreturn. When the instance cannot access the path, the function warns and then runs the directory query against that path anyway. For an S3 path it warns and goes on with$pathSepunset. The twoTest-DbaPathchecks at 62 and 65 are one check twice:$pathand$Pathare the same variable. - Set-DbaPrivilege, lines 389-394: when the remoting check fails, the command only writes a warning.
-EnableExceptionnever throws for it, so a script that relies on the exception carries on as if the privileges had been granted. - Get-DbaComputerCertificate, lines 129-130:
-Pathfails on PowerShell 7.X509Certificate2.Import()is not supported there; the command returns nothing and warns "Issue connecting to computer | X509Certificate is immutable on this platform", which also points to the wrong cause. Reproduced with a .cer file on PowerShell 7.6; Windows PowerShell 5.1 returns the certificate. The integration test skips on PowerShell 7 for this reason (tests/Get-DbaComputerCertificate.Tests.ps1:28). The constructor that takes the bytes works on both. - Copy-DbaRegServer: the only registered server command without
Disconnect-RegServer. It opens the stores of the source and of every destination through Get-DbaRegServerStore (lines 323 and 338) and never closes them; the other nine registered server commands call it since #10577 and #10633. The effect is not measured yet. - Install-DbaFirstResponderKit: since First Responder Kit 8.34 (2026-07-08), sp_Blitz needs sp_ineachdb.
-OnlyScript sp_Blitz.sql, as in the example at line 123, installs a procedure that fails at runtime with "Could not find stored procedure 'dbo.sp_ineachdb'" (seen in our lab on 2026-09-20). The command could add sp_ineachdb.sql when sp_Blitz.sql is selected, or at least the example and the help of-OnlyScriptshould name the dependency.
Smaller ones
- Invoke-DbaAdvancedUpdate, line 153: the debug message counts
$Actions, but the parameter is$Action, so it always reports 0 actions. Lines 231 and 233 write two progress messages directly after each other, so the first one is never readable. - Invoke-DbaDbLogShipping, lines 1109 and 1413:
$host.ui.PromptForChoice($title, ...)with$titlenever set, so the prompt has no caption. - Invoke-DbaDbClone, line 228:
$server.VersionMajor -lt 13 - ($server.VersionMajor -eq 13 -and ...)subtracts the boolean from 13 before comparing. Latent, because the check at line 214 already stops before that for SQL Server 2016 RTM;-lt 13says what is meant. - Get-DbaWaitResource, line 125:
stop-functionin lower case. It works; it is the only call written that way. - Get-OfflineSqlFileStructure (private): no caller anywhere in the module. Remove it?
This text was created by Claude and reviewed by Andreas Jordan.
- Lenguaje dominante
- PowerShell
- Estrellas
- 2.9k
- Forks
- 869
- Merge medio
- 2 d 4 h
- PR fusionados (30 d)
- 38
Preparar el entorno
Inicia el contenedor de desarrollo del proyecto en tu navegador, con tu propia cuenta de GitHub.
- Sin Dockerfile ni archivo de Docker Compose
- Tiene una plantilla de pull request
- Leer la guía de contribución
Primeros pasos
- Lee el issue completo y luego la guía de contribución del proyecto.
- Comenta en el issue que vas a ocuparte — evita que dos personas hagan lo mismo.
- Haz un fork del repositorio y trabaja en una rama.
- Abre un pull request que haga referencia al número del issue.
Más de dataplat/dbatools
-
bugs life triage required
Dificultad 2/5 1-3 horas Aptitud para principiantes 65/100
Los mantenedores suelen responder en 2 días
-
bugs life triage required
Dificultad 2/5 1-3 horas Aptitud para principiantes 75/100
Los mantenedores suelen responder en 2 días
-
Invoke-DbaDbPiiScan - Fix broken PII patterns, add Nordic known names, and proposals for metadata-only scan and native classificationPosiblemente ocupada Un pull request vinculado a esta issue está abierto o ya se fusionó. Abierto
Dificultad 3/5 1-2 días Aptitud para principiantes 35/100
Los mantenedores suelen responder en 2 días
-
bugs life triage required
Dificultad 4/5 3-5 días Aptitud para principiantes 48/100
dataplat/dbatools#10860 · 1 comentario ·
Los mantenedores suelen responder en 2 días
-
bugs life Chrissy needed
Dificultad 3/5 Medio día Aptitud para principiantes 38/100
Los mantenedores suelen responder en 2 días
Todos los issues de dataplat/dbatools
Issues similares
-
Dificultad 2/5 1-3 horas Aptitud para principiantes 64/100
Los mantenedores suelen responder en 1 día
-
bug
Dificultad 2/5 1-3 horas Aptitud para principiantes 85/100
Los mantenedores suelen responder en 1 día
-
bug db/postgres user-priority/P1
Dificultad 2/5 1-3 horas Aptitud para principiantes 72/100
Los mantenedores suelen responder en 1 día
-
Dificultad 2/5 1-3 horas Aptitud para principiantes 80/100
kagent-dev/kagent#3789 ·
Los mantenedores suelen responder en 1 día
-
bug
Dificultad 2/5 1-3 horas Aptitud para principiantes 74/100
Los mantenedores suelen responder en 1 día