Research direction
Start by reviewing the existing device options listed in the issue and the probe wiring support for Cambridge Neurotech and Intan devices. Reproduce the 16-channel mismatch with the ASSY-1-P-2 probe, then trace how device mappings are selected. Done means this probe can be wired to its compatible device without the 32-versus-16 channel assertion.
Written by the indexing model from the issue text.
Description
I posted this on the main spike interface issue page and was suggested the following:
"Looks like we don't have wiring to RHD2216 yet. I would open this issue on the probeinterface repo so that it can be put on the todo list over there. We have tools to allow you to do it manually if you want help with that and if you get that working then you can actually share the mapping with us and we can include it in probeinterface in the future."
We recently switched from a Cambridge Neurotech 64 channel probe to a Cambridge Neurotech 16 channel probe that uses an omnetics adapter to connect to our Intan 16 channel headstage. We are trying to analyze a group of our data obtained with this set-up but are not able to wire to any of the devices that are listed as an option for these probes.
Our probes are: ASSY-1-P-2 - cambridgeneurotech - 16ch - 1shanks
The device options made available are:
['H32>RHD2132',
'ASSY-156>RHD2164',
'ASSY-116>RHD2132',
'ASSY-77>Adpt.A64-Om32_2x-sm-NN>RHD2164',
'ASSY-77>Adpt.A64-Om32_2x-sm-NN>two_RHD2132',
'cambridgeneurotech_mini-amp-64']
All of these appear to be 32 to channel or 64 channel which then read the error: "AssertionError: chan_indices 32 != contact count 16"
Can you help us identify how we can fix this problem?
- Dominant language
- Python
- Stars
- 85
- Forks
- 49
- Avg merge
- 13h 47m
- Merged PRs (30d)
- 3
Contributor guide
No contributing guide indexed for this repository
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from SpikeInterface/probeinterface
-
Difficulty 4/5 3-5 days Newbie friendliness 58/100
SpikeInterface/probeinterface#469 · 2 comments ·
-
Difficulty 3/5 1-2 days Newbie friendliness 68/100
SpikeInterface/probeinterface#465 ·
-
Difficulty 5/5 Over a week Newbie friendliness 48/100
SpikeInterface/probeinterface#452 · 1 comment ·
-
question
Difficulty 4/5 3-5 days Newbie friendliness 45/100
SpikeInterface/probeinterface#449 · 7 comments ·
-
Difficulty 5/5 Over a week Newbie friendliness 30/100
SpikeInterface/probeinterface#447 · 2 comments · 1 reaction ·
All issues in SpikeInterface/probeinterface
Similar issues
-
bug
Difficulty 2/5 1-3 hours Newbie friendliness 82/100
-
Difficulty 2/5 1-3 hours Newbie friendliness 88/100
use-agent-os/agent-os#3314 ·
-
Difficulty 2/5 1-3 hours Newbie friendliness 75/100
BasedHardware/omi#15662 · 1 comment ·
-
documentation help wanted
Difficulty 2/5 1-3 hours Newbie friendliness 90/100
-
Difficulty 2/5 1-3 hours Newbie friendliness 62/100
AiursoftWeb/AnduinOS-2#19 ·