Update newly added CLMU technote section with indoor humidity and air-conditioning dehumidification
Maintainers usually reply within 1 day
@olyson is already working on this.
Since Sep 2, 2026.
Assessment
This issue has not been assessed yet.
Description
(Please see our contribution guidelines for documentation.)
What sort(s) of documentation issue is this?
- Something is missing and/or needs updating.
What part(s) of the documentation does this concern?
- Technical Note (science and design of the model)
- User's Guide (using the model and related tools)
Describe the issue
Copied from #4164:
The code changes add indoor humidity and air-conditioning dehumidification to the CLMU BEM. It prognoses indoor specific humidity, calculates sensible cooling and latent dehumidification loads, and diagnoses condensate production and routes the condensate into urban runoff. The behavior is controlled by an integer CLM namelist variable, building_humidity_mode:
- 0: use the existing CLMU formulation without indoor humidity or AC dehumidification;
- 1: enable indoor humidity and latent heat exchange, but no AC dehumidification (requires prognostic building temperature, building_temp_method=1); and
- 2: enable indoor humidity, latent heat exchange, dehumidification load, and condensate production (requires prognostic building temperature, urban_hac to be ON or ON_WASTEHEAT and urban_explicit_ac=.true.).
The default is set to 0 to ensure bit-for-bit reproducibility with the original scheme.
Additional context (optional)
Currently blocked by #4179.
- Dominant language
- Fortran
- Stars
- 362
- Forks
- 372
- Avg merge
- 1d 11h
- Merged PRs (30d)
- 9
Getting set up
- No Dockerfile or Docker Compose file
- Has a pull request template
- Read the contributing guide
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from ESCOMP/CTSM
-
b4b code health next
Difficulty 2/5 1-3 hours Newbie friendliness 68/100
ESCOMP/CTSM#4330 · 1 comment ·
Maintainers usually reply within 1 day
-
good first issue next size: small test: python usability
Difficulty 2/5 1-3 hours Newbie friendliness 62/100
Maintainers usually reply within 1 day
-
b4b next size: small
Difficulty 1/5 Under an hour Newbie friendliness 70/100
Maintainers usually reply within 1 day
-
Remove ARSLu and ESLgS from the list of available PLUMBER2 sites displayed by running run_tower --helpPossibly taken @samsrabin claimed this 8 days ago. Openb4b good first issue priority: low usability
Difficulty 1/5 Under an hour Newbie friendliness 72/100
ESCOMP/CTSM#4313 · 2 comments · 1 assignee ·
Maintainers usually reply within 1 day
-
b4b usability
Difficulty 2/5 1-3 hours Newbie friendliness 68/100
Maintainers usually reply within 1 day