Description of Issue/Question

If a BGP neighbour is Admin shutdown, the key "is_enabled" has value True instead of False

Did you follow the steps from https://github.com/napalm-automation/napalm#faq

  • [* ] Yes
  • No

napalm-ios version

napalm-ios==0.6.2

IOS version

Cisco IOS Software, s2t54 Software (s2t54-ADVIPSERVICESK9-M), Version 15.2(1)SY1a, RELEASE SOFTWARE (fc6)

Steps to Reproduce the Issue

In case the bgp neighbour 10.1.1.1 is shutdown, the output from "show bgp all summary" is: .. 10.1.1.1 4 65001 0 0 1 0 0 never Idle (Admin) ... but the "Admin" string is not parsed correctly and the result is:

"10.1.1.1": { ... "is_enabled": true, "is_up": false,

The problem is in the line 1198 inside the ios.py which strips the "Admin" string because it is the 11th element inside the list: fields = line.split()[:10]

and so it never gettes into "state_prefix" variable for later check:

if '(Admin)' in state_prefix: is_enabled = False else: is_enabled = True

if I for example remove the [:10] and concatenate last two strings Idle and (Admin), the it works fine:

fields = line.split() if len(fields) > 10: fields[9] = fields[9] + fields[10] fields = fields[:10]

"10.1.1.1": {... "is_enabled": false, "is_up": false,


Moved from https://github.com/napalm-automation/napalm-ios/issues/161