pingcap/tidb
Vedi su GitHubThe update statement reported the truncate error message isn’t compatible with MySQL after column type change
Open
#24.642 aperta il 13 mag 2021
help wantedseverity/moderatesig/sql-infratype/bug
Metriche repository
- Star
- (40.090 star)
- Metriche merge PR
- (Merge medio 14g 4h) (346 PR mergiate in 30 g)
Descrizione
Bug Report
Please answer these questions before submitting your issue. Thanks!
1. Minimal reproduce step (Required)
create table t(a char(250) CHARACTER SET utf8);
insert into t set a="";
alter table t modify a char(120) charset binary;
update t set a = 1624877308284165695 where a = 6130350361147116967;
2. What did you expect to see? (Required)
ERROR 1292 (22007): Truncated incorrect DOUBLE value: '0123456789abc\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x0'
3. What did you see instead (Required)
ERROR 1292 (22007): Truncated incorrect FLOAT value: ''
4. What is your TiDB version? (Required)
Release Version: v4.0.0-beta.2-2889-gaa3e64d08 Edition: Community Git Commit Hash: aa3e64d08bf19c7230cc3b53c3a57f68a50ae3c3 Git Branch: master