  1. What did you do? If possible, provide a recipe for reproducing the error.
select INET_ATON( 35 ) DIV -1;
  1. What did you expect to see?
mysql> select INET_ATON( 35 ) DIV -1;
ERROR 1690 (22003): BIGINT UNSIGNED value is out of range in '(inet_aton(35) DIV -(1))'
  1. What did you see instead?
mysql> select INET_ATON( 35 ) DIV -1;
ERROR 1690 (22003): BIGINT UNSIGNED value is out of range in '(35, -1)'
  1. What version of TiDB are you using (tidb-server -V or run select tidb_version(); on TiDB)? fdbc149b7