CambridgeNeurotech ASSY-325D H10 & E-1 probes inconsistent with documentation
Nobody has claimed this yet.
Assessment
- Difficulty
- 3/5
- Estimated time
- 1-2 days
- Newbie friendliness
- 45/100
- Issue type
- Bug
- Clarity
- Mostly clear
- Activity status
- Quiet
- Domain
- data
Research direction
Compare the repository images at cambridgeneurotech/ASSY-325D-H10/ASSY-325D-H10.png and cambridgeneurotech/ASSY-325D-E-1/ASSY-325D-E-1.png with the linked Cambridge Neurotech mapping PDFs. Verify the channel ordering, vertical orientation, and conical shank geometry, then update the probe descriptions so both versions match the documentation.
Written by the indexing model from the issue text.
Description
The channel IDs and the geometry of the version here seems inconsistent with documentation.
ASSY-325D H10: Firstly the channels should be vertically flipped and mapped in this order.
ASSY-325D E-1: Seems quite inconsistent with documentation. The geometry should be along inclination of shank in a conical fashion
I'm not sure maybe this version refers to some old version or is just incorrect
documentation:
ASSY-325D H10:: https://www.cambridgeneurotech.com/assets/files/ASSY-325D-H10_H10-2-map.pdf
ASSY-325 E1-D: https://www.cambridgeneurotech.com/assets/files/ASSY-325D-E-1_E-2-map.pdf
your versions:
https://github.com/SpikeInterface/probeinterface_library/blob/main/cambridgeneurotech/ASSY-325D-H10/ASSY-325D-H10.png
https://github.com/SpikeInterface/probeinterface_library/blob/main/cambridgeneurotech/ASSY-325D-E-1/ASSY-325D-E-1.png
- Dominant language
- TypeScript
- Stars
- 21
- Forks
- 11
- Avg merge
- 22h 23m
- Merged PRs (30d)
- 2
Contributor guide
No contributing guide indexed for this repository
First steps
- Read the whole issue, then the project's contributing guide.
- Comment on the issue to say you are picking it up — it saves two people doing the same work.
- Fork the repository and make your change on a branch.
- Open a pull request that references the issue number.
More from SpikeInterface/probeinterface_library
-
Difficulty 5/5 Over a week Newbie friendliness 35/100
-
Difficulty 3/5 1-2 days Newbie friendliness 62/100
SpikeInterface/probeinterface_library#73 · 5 comments ·
All issues in SpikeInterface/probeinterface_library
Similar issues
-
bug(cli): hapi doctor inline-media prints a fabricated B:\ helper-script path in packaged installs Open
Difficulty 2/5 1-3 hours Newbie friendliness 70/100
-
Crush Open
Difficulty 1/5 Under an hour Newbie friendliness 85/100
catppuccin/catppuccin#3125 ·
-
Add a SECURITY.md Open
Difficulty 1/5 Under an hour Newbie friendliness 90/100
ElementsProject/cln-application#167 · 1 comment · 1 reaction ·
-
Difficulty 2/5 1-3 hours Newbie friendliness 75/100
Quantco/pnpm-licenses#17 ·
-
Difficulty 2/5 1-3 hours Newbie friendliness 75/100